iTHERM FlameLine TAF12T High Temperature Thermometer

Brand: Endress+Hauser

iTHERM FlameLine TAF12T High Temperature Thermometer

Brand: Endress+Hauser
Extended Extended

Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators
  • Process temperatures: up to +1700 °C (+3092 °F)
Features
  • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
  • Long term stable measurement due to sensor protection with non-porous materials
  • Flexible product selection by modular design
  • Optimized life cycle costs by means of replaceable spare parts

Specifications

Measuring Principle

  • Thermocouple

Characteristic / Application

  • metric style
  • modular temperature assembly
  • high temperature (furnace)
  • ncl. triple ceramic thermowell

Thermowell / Protection Tube

  • ceramic protection tube and 2x inner tube

Insert / Probe

  • ceramic capilarry, rigid

Outer Diameter Protection Tube / Insert

  • 24.0 mm (0.94")
  • 26.0 mm (1.02")

Max. Immersion Length on Request

  • up to 3,500.00 mm (137.80'')

Material Protection Tube/ Thermowell

  • Ceramic (C530/C610/C799)

Process Connection

  • compression fitting: G1-1/2"

Tip Shape

  • straight

Operating Temperature

  • Type S: 0 °C ...1,600 °C (32 °F ...2,912 °F)
  • Type R: 0 °C ...1,600 °C (32 °F ...2,912 °F)
  • Type B: 600 °C ...1,700 °C (1,112 °F ...3,092 °F)

Max. Process Pressure (static)

  • at 20 °C: 1 bar (15 psi)

Accuracy

  • class 2 acc. to IEC 60584

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Certification

  • SIL (transmitter only)