iTHERM FlameLine TAF12T High Temperature Thermometer
Brand: Endress+HauseriTHERM FlameLine TAF12T High Temperature Thermometer
Brand: Endress+Hauser
Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
- The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators
- Process temperatures: up to +1700 °C (+3092 °F)
- Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
- Long term stable measurement due to sensor protection with non-porous materials
- Flexible product selection by modular design
- Optimized life cycle costs by means of replaceable spare parts
Specifications
Brand
Measuring Principle
- Thermocouple
Characteristic / Application
- metric style
- modular temperature assembly
- high temperature (furnace)
- ncl. triple ceramic thermowell
Thermowell / Protection Tube
- ceramic protection tube and 2x inner tube
Insert / Probe
- ceramic capilarry, rigid
Outer Diameter Protection Tube / Insert
- 24.0 mm (0.94")
- 26.0 mm (1.02")
Max. Immersion Length on Request
- up to 3,500.00 mm (137.80'')
Material Protection Tube/ Thermowell
- Ceramic (C530/C610/C799)
Process Connection
- compression fitting: G1-1/2"
Tip Shape
- straight
Operating Temperature
- Type S: 0 °C ...1,600 °C (32 °F ...2,912 °F)
- Type R: 0 °C ...1,600 °C (32 °F ...2,912 °F)
- Type B: 600 °C ...1,700 °C (1,112 °F ...3,092 °F)
Max. Process Pressure (static)
- at 20 °C: 1 bar (15 psi)
Accuracy
- class 2 acc. to IEC 60584
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification
- SIL (transmitter only)