Compact Conductivity Device Smartec CLD18
Brand: Endress+HauserCompact Conductivity Device Smartec CLD18
Brand: Endress+Hauser
Smartec CLD18 is the cost-effective solution for all applications in beverage plants where small tubes are used and where the toroidal measurement is used as a switch function. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Smartec CLD18 ensures the Overall Equipment Effectiveness (OEE) of your plant thanks to fast and reliable CIP and optional IO-Link protocol.
The hygienic Smartec CLD18 measures toroidal conductivity in beverage applications:
- Control of CIP processes in the return channel
- Concentration control in remaking of CIP cleaning agents
- Product monitoring in pipe systems, bottling plants
- Beer - Push water interphase
- Beer - Water cut for brewing lines
- Leakage monitoring
It features the following protocols and interfaces:
- 0/4...20mA
- IO-Link (optional)
- Unique hygienic design avoids contamination
- 3-A approval
- Compliant with EG 2023/2006 and 1935/2004
- Suitable for cleaning-in-place (CIP)
- Smart and easy integration into your plant infrastructure thanks to optional IO-Link protocol
- Compact design permits installation in small tubes without restricting the flow
Specifications
Brand
Measuring Principle
- Inductive
Application
- Food and beverage industries
Characteristic
- Specifically intended for use in beverage industry applications and especially suitable for: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring Range
- 200 µS/cm to 1000 mS/cm
- Cell constant k: 11.0 1/cm
Design
- Hygienic design with FDA certified virgin PEEK
Material
- Sensor: PEEK
- Process connection 1.4435 (316L)
- Seal: EPDM
Process Temperature
- -10 °C to 110 °C (14 °F to 230 °F)
- Sterilization: max. 130 °C at 6 bar abs up to 60 min (Max. 266 °F at 87 psi up to 60 min)
Process Pressure
- 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
- 7.75 bar abs at 110 °C (112 psi at 230 °F)
- 6.0 bar abs at 130 °C (87 psi at 266 °F) for max. 60 minutes
Temperature Sensor
- Pt 1000 (class B)
Connection
- Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
- ISO 2852, SMS-2", Varivent N DN 40-125
- Thread G1-1/2 SS, G1-1/2 PVC , Union nut 2-1/4 Inch PVC
Ingress Protection
- IP69
Output / Communication
- 0/4...20mA
- IO-Link (option)
Additional Certifications
- 3A, FDA, EHEDG
- EC Regulation No. 1935/2004