The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts.

  • For all kinds of process vessels, like reactors, autoclaves, separators, acid tanks, cyclones
  • For liquids, solids, suspensions or sludges etc.
  • Extreme measuring conditions, for example corrosion, abrasion, viscosity, toxicity
  • Process temperature: No limitation (non-invasive)
  • Process pressure: No limitation (non-invasive)
  • Housing material: 316L, aluminum
  • International explosion protection certificates, SIL, overfill prevention WHG
Features
  • First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts
  • Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter
  • Increased plant safety, efficiency and availability even under extreme process and ambient conditions
  • Designed according to IEC 61508 with SIL2/3 approval for all measuring tasks
  • Reduced verification effort and minimized plant shut-downs due to state-of-art Heartbeat Technology
  • Usage in up to +80°C (+176°F) ambient temperature without additional cooling thanks to innovative sensor technology
  • Bluetooth® wireless technology for remote operation out of the radiation beam

Specifications

Measuring Principle

  • Radiometric

Characteristic / Application

  • Compact transmitter for extreme process conditions (temperature, pressure)
  • Non-contact measuring technique

Interface Measurement

  • Interfaces liquid / liquid also with emulsion layers
  • Interfaces liquid / solid

Specialities

  • Heartbeat Technology
  • SIL 2/3 according to IEC 61508
  • Bluetooth® commissioning, operation and maintenance with the SmartBlue App

Supply / Communication

  • 2-wire loop powered

Accuracy

  • +/- 1%

Ambient Temperature

  • -40 °C...+80 °C (-40 °F...+176 °F)

Process Temperature

  • Any

Process Pressure / Max. Overpressure Limit

  • Any

Main Wetted Parts

  • Non-contact

Process Connection

  • Non-contact

Sensor Length

  • PVT scintillator
  • 400 mm...3000 mm
  • >3000 mm cascade mode

Max. Measurement Distance

  • Unlimited measuring range
  • Cascade

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

Safety Approvals

  • Overfill protection WHG
  • SIL 2/3

Design Approvals

  • EN 10204-3.1

Options

  • Display

Components

  • Isotope: FSG60, FSG61
  • Source container: FQG60, FQG61, FQG62, FQG63, FQG66
  • Mounting accessories: FHG61