Conductive Point Level Detection Double Rod Probe 11362Z

Brand: Endress+Hauser

Conductive Point Level Detection Double Rod Probe 11362Z

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Lean Lean

The 11362Z is a high resistant probe for applications requiring accurate point level detection or overfill prevention in plastic vessels or vessels made of non-conducting material. The two-point control can be carried out in vessels with electrically conducting walls.

For vessels made of plastic or non-conducting material. for applications in explosion hazardous areas, in waste water plants, which are sometimes regarded as Zone 0 or as overfill prevention for water-polluting liquids.

  • Process connections: Threads and flanges
  • Measuring range: 100 to 4,000mm (5.9 to 157")
  • Temperature: -50 to +150°C (-58 to +302°F)
  • Pressure: -1 to +30bar (-15 to +435psi)
  • Components: Transmitter FTW325
  • International explosion protection certificates, overfill prevention WHG
Features
  • Reliable and safe measurement
  • Safe measurement even for applications in explosion hazardous area
  • Variable process connections for various applications

Specifications

Measuring Principle

  • Conductive

Characteristic / Application

  • Double rod probe with high-class media contacting wetted parts

Supply / Communication

  • Relay

Ambient Temperature

  • -20 °C ... 80 °C
  • -4 °F ... 176 °F

Process Temperature

  • -40 °C ... 150 °C
  • -40 °F ... 302 °F

Process Pressure / Max. Overpressure Limit

  • Vacuum ... 30 bar
  • Vacuum ... 435 psi

Min. Conductivity of Medium

  • 20 µS/cm

Main Wetted Parts

  • PTFE, PFA, 316 TI, Alloy B/C4, Titan, Tantal, Monel

Process Connection

  • G 1-1/2A
  • NPT1-1/2"
  • Flange DIN /ASME

Sensor Length

  • 0.1m ... 4m
  • 4ft ... 157ft

Communication

  • Relay

Certificates / Approvals

  • ATEX, NEPSI

Components

  • Transmitter: FTW325

Application Limits

  • Observe min medium conductivity
show more