Vibronic Point Level

Point level switches in liquids and solids.

1 - 31 of 31 Products
Liquiphant FTL80/81/85 FTL81
Endress+Hauser
Liquiphant FTL80/81/85 FTL81
Xpert Xpert
Request Information
Probe 11375Z
Endress+Hauser
Probe 11375Z
Lean Lean
Request Information
Liquiphant FTL62/63/64 FTL63
Endress+Hauser
Liquiphant FTL62/63/64 FTL63
Request Information
Liquiphant FTL62/63/64 FTL64
Endress+Hauser
Liquiphant FTL62/63/64 FTL64
Request Information
Probe 11363Z
Endress+Hauser
Probe 11363Z
Lean Lean
Request Information
Vibronic level switch Liquiphant FTL43
Endress+Hauser
Vibronic level switch Liquiphant FTL43
Lean Lean
Request Information
Probe 11362Z
Endress+Hauser
Probe 11362Z
Lean Lean
Request Information
Nivotester FTL325N/325P/375P FTL325P
Endress+Hauser
Nivotester FTL325N/325P/375P FTL325P
Extended Extended
Request Information
Nivotester FTL825
Endress+Hauser
Nivotester FTL825
Xpert Xpert
Request Information
Capacitance level switch Nivotester FTW325
Endress+Hauser
Capacitance level switch Nivotester FTW325
Lean Lean
Request Information
Vibronic level switch Liquiphant FTL31/33 FTL33
Endress+Hauser
Vibronic level switch Liquiphant FTL31/33 FTL33
Fundamental Fundamental
Request Information
Liquiphant FTL80/81/85 FTL85
Endress+Hauser
Liquiphant FTL80/81/85 FTL85
Xpert Xpert
Request Information
Transmitter NRR26x NRR262
Endress+Hauser
Transmitter NRR26x NRR262
Request Information
Soliphant FTM5x FTM52
Endress+Hauser
Soliphant FTM5x FTM52
Extended Extended
Request Information
Vibronic level switch Soliphant FTM2x FTM21
Endress+Hauser
Vibronic level switch Soliphant FTM2x FTM21
Fundamental Fundamental
Request Information
Vibronic level switch Soliphant FTM5x FTM51
Endress+Hauser
Vibronic level switch Soliphant FTM5x FTM51
Extended Extended
Request Information
Vibronic level switch Liquiphant FTL50/H, FTL51/C/H FTL51H
Endress+Hauser
Vibronic level switch Liquiphant FTL50/H, FTL51/C/H FTL51H
Extended Extended
Request Information
Vibronic level switch Soliphant FTM2x FTM20
Endress+Hauser
Vibronic level switch Soliphant FTM2x FTM20
Fundamental Fundamental
Request Information
Transmitter NRR26x NRR261
Endress+Hauser
Transmitter NRR26x NRR261
Request Information
Probe 11961Z
Endress+Hauser
Probe 11961Z
Lean Lean
Request Information
Vibronic level switch Liquiphant FTL31/33
Endress+Hauser
Vibronic level switch Liquiphant FTL31/33
Fundamental Fundamental
Request Information
Nivotester FTL325N/325P/375P
Endress+Hauser
Nivotester FTL325N/325P/375P
Extended Extended
Request Information
Vibronic level switch Soliphant FTM5x FTM50
Endress+Hauser
Vibronic level switch Soliphant FTM5x FTM50
Extended Extended
Request Information
Liquiphant FTL41
Endress+Hauser
Liquiphant FTL41
Lean Lean
Request Information
Oil Leak Detector NAR300
Endress+Hauser
Oil Leak Detector NAR300
Xpert Xpert
Request Information
Vibronic level switch Liquiphant FTL51B
Endress+Hauser
Vibronic level switch Liquiphant FTL51B
Request Information
Liquiphant FTL62/63/64
Endress+Hauser
Liquiphant FTL62/63/64
Request Information
Capacitance level switch Nivotester FTC325
Endress+Hauser
Capacitance level switch Nivotester FTC325
Extended Extended
Request Information
Liquiphant FTL80/81/85
Endress+Hauser
Liquiphant FTL80/81/85
Xpert Xpert
Request Information
Liquiphant FTL50/H, FTL51/C/H FTL50H
Endress+Hauser
Liquiphant FTL50/H, FTL51/C/H FTL50H
Extended Extended
Request Information
Probe 11371
Endress+Hauser
Probe 11371
Lean Lean
Request Information

Vibronic Point Level Detection

Endress+Hauser’s vibronic point level devices are switches using a vibrating tuning fork. Electronics watch resonance; when the product covers the fork, the frequency shifts and the output toggles. Liquiphant (liquids) and Soliphant (solids) offer short/extended probes for standard, hygienic, or rugged service.

They require no calibration and are largely independent of density and dielectric. The fork ignores bubbles, vapor, and agitation, giving repeatable switching where floats or capacitance drift. Self‑monitoring and proof‑testing support SIL 2/3; diagnostics flag corrosion or buildup, and MIN/MAX fail‑safe protects on fault or power loss.

Integration: threaded, flanged, and hygienic clamp connections; stainless‑steel wetted parts; approvals for hazardous areas and overfill protection. Commissioning via push‑buttons or guided setup. Outputs include relay, 2‑wire AC/DC, NAMUR, and transistor types; some compact versions add IO‑Link for easy PLC integration.

Typical uses: overfill prevention, high‑high/low‑low alarms, pump run‑dry, leak detection, and filter housings. In solids, they signal "full" or "empty" in hoppers, chutes, and dust filters. This is common across various industries such as chemicals, water, food & beverage, oil & gas, and pharma. For extreme viscosity or heavy buildup, use alternatives or forks with coating compensation.

TriNova, your trusted Endress+Hauser Representative since 2002.