Vibronic Point Level Detection Liquiphant FTL85

Brand: Endress+Hauser

Vibronic Point Level Detection Liquiphant FTL85

Brand: Endress+Hauser
Xpert Xpert

Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations, or build-up.

  • Process connections: Threads and flanges
  • Temperature: -50 to +150°C (-76 to +300°F)
  • Pressure: -1 to +40bar (-14.5 to +580psi)
  • Sensor length: Extension pipe up to 3m (9.8ft)
  • Sensor material: Enamel, ECTFE and various PFA materials
  • International explosion protection certificates, overfill protection WHG, SIL
Features
  • Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
  • Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
  • Permanent self-monitoring/internal redundancy
  • 4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
  • No adjustment: quick, low-cost startup
  • No mechanically moving parts: no maintenance, no wear, long operating life
  • Monitoring of fork for damage, corrosion, buildup and mechanical blocking

Specifications

Measuring Principle

  • Vibration Liquids

Characteristic / Application

  • Coated point level switch for MIN and MAX safety applications up to SIL3,
  • Dual Sealing/ Second line of defense,
  • Modular housing concept

Specialities

  • Permanent LIVE signal monitors function safety
  • Failsafe design
  • High availability of the measuring values

Supply / Communication

  • 2-wire 4...20 mA

Ambient Temperature

  • -50°C...+70°C
  • (-58°F...+160°F)

Process Temperature

  • –50°C...+150°C
  • (–58°F...+300°F)

Process Pressure / Max. Overpressure Limit

  • Vacuum...40 bar
  • (580 psi)

Min. Density of Medium

  • Density from 0.4 g/cm3
  • (0.4 SGU)

Main Wetted Parts

  • With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials

Process Connection

  • Flange
  • DN25...DN100,
  • ASME 1"...4",
  • JIS 10K...20K

Sensor Length

  • Extension pipe up to 3 m (9.8 ft)

Communication

  • 2-wire 4...20 mA

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

Safety approvals

  • Overfill protection WHG
  • Leakage Detection
  • SIL3

Options

  • AlloyC Material
  • PWIS free
  • Pressure tight feed through
  • Weather protection

Components

  • Nivotester FTL825, Transmitter
show more