Vibronic Point Level Detection Liquiphant FTL85
Brand: Endress+HauserVibronic Point Level Detection Liquiphant FTL85
Brand: Endress+Hauser
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations, or build-up.
- Process connections: Threads and flanges
- Temperature: -50 to +150°C (-76 to +300°F)
- Pressure: -1 to +40bar (-14.5 to +580psi)
- Sensor length: Extension pipe up to 3m (9.8ft)
- Sensor material: Enamel, ECTFE and various PFA materials
- International explosion protection certificates, overfill protection WHG, SIL
- Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
- Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
- Permanent self-monitoring/internal redundancy
- 4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
- No adjustment: quick, low-cost startup
- No mechanically moving parts: no maintenance, no wear, long operating life
- Monitoring of fork for damage, corrosion, buildup and mechanical blocking
Specifications
Brand
Measuring Principle
- Vibration Liquids
Characteristic / Application
- Coated point level switch for MIN and MAX safety applications up to SIL3,
- Dual Sealing/ Second line of defense,
- Modular housing concept
Specialities
- Permanent LIVE signal monitors function safety
- Failsafe design
- High availability of the measuring values
Supply / Communication
- 2-wire 4...20 mA
Ambient Temperature
- -50°C...+70°C
- (-58°F...+160°F)
Process Temperature
- –50°C...+150°C
- (–58°F...+300°F)
Process Pressure / Max. Overpressure Limit
- Vacuum...40 bar
- (580 psi)
Min. Density of Medium
- Density from 0.4 g/cm3
- (0.4 SGU)
Main Wetted Parts
- With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials
Process Connection
- Flange
- DN25...DN100,
- ASME 1"...4",
- JIS 10K...20K
Sensor Length
- Extension pipe up to 3 m (9.8 ft)
Communication
- 2-wire 4...20 mA
Certificates / Approvals
- ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC
Safety approvals
- Overfill protection WHG
- Leakage Detection
- SIL3
Options
- AlloyC Material
- PWIS free
- Pressure tight feed through
- Weather protection
Components
- Nivotester FTL825, Transmitter