Vibronic Point Level Detection Liquiphant FTL85

Brand: Endress+Hauser

Vibronic Point Level Detection Liquiphant FTL85

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Xpert Xpert

Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. with high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations, or build-up.

  • Process connections: Threads and flanges
  • Temperature: -50 to +150°C (-76 to +300°F)
  • Pressure: -1 to +40bar (-14.5 to +580psi)
  • Sensor length: Extension pipe up to 3m (9.8ft)
  • Sensor material: Enamel, ECTFE and various PFA materials
  • International explosion protection certificates, overfill protection WHG, SIL
Features
  • Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
  • Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
  • Permanent self-monitoring/internal redundancy
  • 4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
  • No adjustment: quick, low-cost startup
  • No mechanically moving parts: no maintenance, no wear, long operating life
  • Monitoring of fork for damage, corrosion, buildup and mechanical blocking

Specifications

Product Family

  • Liquiphant

Measuring Principle

  • Vibration Liquids

Characteristic / Application

  • Coated point level switch for MIN and MAX safety applications up to SIL3,
  • Dual Sealing/ Second line of defense,
  • Modular housing concept

Specialities

  • Permanent LIVE signal monitors function safety
  • Failsafe design
  • High availability of the measuring values

Supply / Communication

  • 2-wire 4...20 mA

Ambient Temperature

  • -50°C...+70°C
  • (-58°F...+160°F)

Process Temperature

  • –50°C...+150°C
  • (–58°F...+300°F)

Process Pressure / Max. Overpressure Limit

  • Vacuum...40 bar
  • (580 psi)

Min. Density of Medium

  • Density from 0.4 g/cm3
  • (0.4 SGU)

Main Wetted Parts

  • With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials

Process Connection

  • Flange
  • DN25...DN100,
  • ASME 1"...4",
  • JIS 10K...20K

Sensor Length

  • Extension pipe up to 3 m (9.8 ft)

Communication

  • 2-wire 4...20 mA

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

Safety approvals

  • Overfill protection WHG
  • Leakage Detection
  • SIL3

Options

  • AlloyC Material
  • PWIS free
  • Pressure tight feed through
  • Weather protection

Components

  • Nivotester FTL825, Transmitter
show more