iTHERM ModuLine TM412 Hygienic Modular Thermometer

Brand: Endress+Hauser

iTHERM ModuLine TM412 Hygienic Modular Thermometer

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

  • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
  • Measuring range: –200 to +600 °C (–28 to +1 112 °F)
  • Pressure range up to 40 bar (580 psi)
  • Protection class: up to IP69K
Features
  • User-friendly and reliable from product selection to maintenance
  • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
  • iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
  • iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration
  • iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating
  • International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability

Specifications

Product Family

  • iTHERM ModuLine

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • imperial style
  • modular temperature assembly
  • hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
  • hygienic process connections
  • with neck
  • suitable for hazardous areas
  • incl. protection tube
  • iTHERM QuickSens for fastest response time
  • iTHERM StrongSens for most robust design
  • iTHERM QuickNeck for easy and cost saving recalibration

Thermowell / Protection Tube

  • without
  • incl. thermowell
  • incl. Tee-/elbow thermowell

Insert / Probe

  • mineral insulated (MI), flexible
  • pipe version, isolated wires, not flexible

Outer Diameter Protection Tube / Insert

  • 1/4'' (6.35 mm)
  • 3/8'' (9.53 mm)
  • 1/2" (12.7 mm)

Max. Immersion Length on Request

  • 48"

Material Protection Tube/ Thermowell

  • 316L

Process Connection

  • Weld-in adapter
  • Tri-clamp
  • Clamp-connections according to ISO2852
  • G3/4" Liquiphant
  • G1" Liquiphant
  • Varivent
  • T- and elbow thermowell

Tip Shape

  • straight
  • reduced

Surface Roughness Ra

  • 30 μin (0.76 μm)
  • 15 μin (0.38 μm )
  • 15 μin (0.38 μm) electropolished

Operating Temperature

  • PT100 WW: -200 °C … 600 °C (-328 °F … 1,112 °F)
  • iTHERM StrongSens: -50 °C … 500 °C (-58 °F … 932 °F)
  • iTHERM QuickSens: -50 °C … 200 °C (-58 °F … 392 °F)
  • PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)

Max. Process Pressure (static)

  • at 20 °C: 40 bar (580 psi)

Accuracy

  • class B acc. to IEC 60751
  • class A acc. to IEC 60751
  • class AA acc. to IEC 60751

Response Time

  • depending on configuration
  • iTHERM QuickSens: t90 = 1,5 s
  • iTHERM StrongSens: t90 = 9,5 s

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex nA
  • ATEX IECEx Ex ia, Ex tb
  • CSA C/US IS, NI
  • CSA NI
  • CSA IS, NI
  • FM NI
  • FM IS, NI
  • FM+CSA IS, NI

Certification

  • SIL (transmitter only)
show more