iTHERM ModuLine TM412 Hygienic Modular Thermometer

Brand: Endress+Hauser

iTHERM ModuLine TM412 Hygienic Modular Thermometer

Brand: Endress+Hauser
Extended Extended

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

  • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
  • Measuring range: –200 to +600 °C (–28 to +1 112 °F)
  • Pressure range up to 40 bar (580 psi)
  • Protection class: up to IP69K
Features
  • User-friendly and reliable from product selection to maintenance
  • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
  • iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
  • iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration
  • iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating
  • International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability

Specifications

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • imperial style
  • modular temperature assembly
  • hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
  • hygienic process connections
  • with neck
  • suitable for hazardous areas
  • incl. protection tube
  • iTHERM QuickSens for fastest response time
  • iTHERM StrongSens for most robust design
  • iTHERM QuickNeck for easy and cost saving recalibration

Thermowell / Protection Tube

  • without
  • incl. thermowell
  • incl. Tee-/elbow thermowell

Insert / Probe

  • mineral insulated (MI), flexible
  • pipe version, isolated wires, not flexible

Outer Diameter Protection Tube / Insert

  • 1/4'' (6.35 mm)
  • 3/8'' (9.53 mm)
  • 1/2" (12.7 mm)

Max. Immersion Length on Request

  • 48"

Material Protection Tube/ Thermowell

  • 316L

Process Connection

  • Weld-in adapter
  • Tri-clamp
  • Clamp-connections according to ISO2852
  • G3/4" Liquiphant
  • G1" Liquiphant
  • Varivent
  • T- and elbow thermowell

Tip Shape

  • straight
  • reduced

Surface Roughness Ra

  • 30 μin (0.76 μm)
  • 15 μin (0.38 μm )
  • 15 μin (0.38 μm) electropolished

Operating Temperature

  • PT100 WW: -200 °C … 600 °C (-328 °F … 1,112 °F)
  • iTHERM StrongSens: -50 °C … 500 °C (-58 °F … 932 °F)
  • iTHERM QuickSens: -50 °C … 200 °C (-58 °F … 392 °F)
  • PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)

Max. Process Pressure (static)

  • at 20 °C: 40 bar (580 psi)

Accuracy

  • class B acc. to IEC 60751
  • class A acc. to IEC 60751
  • class AA acc. to IEC 60751

Response Time

  • depending on configuration
  • iTHERM QuickSens: t90 = 1,5 s
  • iTHERM StrongSens: t90 = 9,5 s

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex nA
  • ATEX IECEx Ex ia, Ex tb
  • CSA C/US IS, NI
  • CSA NI
  • CSA IS, NI
  • FM NI
  • FM IS, NI
  • FM+CSA IS, NI

Certification

  • SIL (transmitter only)
show more