iTHERM ModuLine TM412 Hygienic Modular Thermometer
Brand: Endress+HauseriTHERM ModuLine TM412 Hygienic Modular Thermometer
Brand: Endress+Hauser
It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
- Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
- Measuring range: –200 to +600 °C (–28 to +1 112 °F)
- Pressure range up to 40 bar (580 psi)
- Protection class: up to IP69K
- User-friendly and reliable from product selection to maintenance
- iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
- iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control
- iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
- iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration
- iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating
- International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Specifications
Brand
Measuring Principle
- Resistance Temperature Detector
Characteristic / Application
- imperial style
- modular temperature assembly
- hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
- hygienic process connections
- with neck
- suitable for hazardous areas
- incl. protection tube
- iTHERM QuickSens for fastest response time
- iTHERM StrongSens for most robust design
- iTHERM QuickNeck for easy and cost saving recalibration
Thermowell / Protection Tube
- without
- incl. thermowell
- incl. Tee-/elbow thermowell
Insert / Probe
- mineral insulated (MI), flexible
- pipe version, isolated wires, not flexible
Outer Diameter Protection Tube / Insert
- 1/4'' (6.35 mm)
- 3/8'' (9.53 mm)
- 1/2" (12.7 mm)
Max. Immersion Length on Request
- 48"
Material Protection Tube/ Thermowell
- 316L
Process Connection
- Weld-in adapter
- Tri-clamp
- Clamp-connections according to ISO2852
- G3/4" Liquiphant
- G1" Liquiphant
- Varivent
- T- and elbow thermowell
Tip Shape
- straight
- reduced
Surface Roughness Ra
- 30 μin (0.76 μm)
- 15 μin (0.38 μm )
- 15 μin (0.38 μm) electropolished
Operating Temperature
- PT100 WW: -200 °C … 600 °C (-328 °F … 1,112 °F)
- iTHERM StrongSens: -50 °C … 500 °C (-58 °F … 932 °F)
- iTHERM QuickSens: -50 °C … 200 °C (-58 °F … 392 °F)
- PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)
Max. Process Pressure (static)
- at 20 °C: 40 bar (580 psi)
Accuracy
- class B acc. to IEC 60751
- class A acc. to IEC 60751
- class AA acc. to IEC 60751
Response Time
- depending on configuration
- iTHERM QuickSens: t90 = 1,5 s
- iTHERM StrongSens: t90 = 9,5 s
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - Approvals
- ATEX Ex nA
- ATEX IECEx Ex ia, Ex tb
- CSA C/US IS, NI
- CSA NI
- CSA IS, NI
- FM NI
- FM IS, NI
- FM+CSA IS, NI
Certification
- SIL (transmitter only)