Analog Conductivity Sensor Indumax CLS54

Brand: Endress+Hauser

Analog Conductivity Sensor Indumax CLS54

Brand: Endress+Hauser

The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands.

Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.

Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:

  • Phase separation of product/water and product/product mixtures in pipe systems
  • Control of CIP (cleaning in place) processes in the return channel
  • Concentration control in remaking of CIP cleaning agents
  • Product monitoring in pipe systems, bottling plants, quality assurance
  • Leakage monitoring

Its unique hygienic design is certified by EHEDG and 3-A.

Features
  • Unique hygienic design avoids contamination
  • With all hygienic certificates required in hygienic applications
  • Food grade virgin PEEK body without joints nor crevices
  • Certified biocompatibility according to USP class VI
  • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
  • Compliant with EG 2023/2006 and 1935/2004

Specifications

Measuring Principle

  • Inductive conductivity measurement

Application

  • Food, beverage and pharmaceutical industries and in biotechnology

Characteristic

  • Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

Measuring Range

  • 100 µS/cm - 2,000 mS/cm Cell constant k: 6,3 1/cm

Design

  • Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications

Material

  • In contact with medium: Virgin PEEK
  • Surface roughness: Ra<0.9 µm

Process Temperature

  • Process temperature: -10 - +125 °C (14 - 257 °F)
  • Sterilisation: 150 °C (302 °F)/5 bar (72.5 psi) (max. 60 min)

Process Pressure

  • 12 bar (174 psi)/20 °C (68 °F)
  • 8 bar (116 psi)/125 °C (257 °F)

Temperature Sensor

  • Pt1000 (class A) with a temperature response time T90 < 27 s

Ex Certification

  • ATEX II G EEx ia IIc T3/T4/T6
  • FM/CSA IS NI CL.I,II,III,Div.1&2 group A-G in connection with the transmitter CM42

Connection

  • Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50

Ingress Protection

  • IP68/NEMA6P

Additional Certifications

  • FDA, EHEDG, 3-A, Biological reactivity (USP class VI part 87 and 88)