Proline T-Mass F 500 Thermal Mass Flowmeter

Brand: Endress+Hauser

Proline T-Mass F 500 Thermal Mass Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended
Heartbeat Technology Heartbeat Technology

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement
  • Measurement of utility and process gases as well as gas mixtures in small line sizes

Device properties

  • Inline version with DN 15 to 100 (1/2 to 4")
  • Bidirectional measurement; high measuring performance
  • Patented drift-free sensor with SIL 2
  • Remote version with up to 4 I/Os
  • Backlit display with touch control and WLAN access
  • Standard cable between sensor and transmitter
Features
  • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
  • High level of process control – premium measurement accuracy and repeatability
  • Reliable monitoring – detection of process disturbances and reverse flow
  • Easy maintenance – removable sensor
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Product Family

  • T-mass

Measuring Principle

  • Thermal

Product Headline

  • Inline flowmeter with long-term stability as remote version with up to 4 I/Os
  • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
  • Measurement of utility and process gases as well as gas mixtures in small line sizes

Sensor Features

  • High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor
  • Inline version with DN 15 to 100 (1/2 to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology
  • Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter

Nominal Diameter Range

  • DN 15 to DN 100 (1/2" to 4")

Wetted Materials

  • Measuring tubes - DN 15 to 50 (1/2 to 2"): stainless cast steel, CF3M/1.4408
  • Measuring tubes - DN 65 to 100 (2-1/2 to 4"): stainless steel, 1.4404 (316/316L)
  • Process connections - flange connection: Stainless steel, 1.4404 (F316/F316L)
  • Process connections - thread connection: Stainless steel, 1.4404 (316/316L)
  • Sensing element - unidirectional: Stainless steel, 1.4404 (316/316L)
  • Sensing element - unidirectional: Alloy C22, 2.4602 (UNS N06022);
  • Sensing element - bidirectional: Stainless steel, 1.4404 (316/316L)
  • Reverse flow detection: Stainless steel, 1.4404 (316/316L)

Measured Variables

  • Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density

Max. Measurement Error

  • Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring Range

  • 0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Max. Process Pressure

  • PN40 / Cl. 300 / 20K

Medium Temperature Range

  • -40 °C to +180°C (-40 °F to +356 °F)

Ambient Temperature

  • -40 to 60°C (-40 to 140°F)
  • Transmitter: -50 to 60°C (-50 to 140°F), optional
  • Sensor: -60 to 60°C (-60 to 140°F), optional

Transmitter Housing Material

  • Aluminium, AlSi10Mg, coated
  • Polycarbonate

Degree of Protection

  • IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible

Outputs

  • 4 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, Modbus RS485

Power Supply

  • DC 24V
  • AC 100 to 240V

Hazardous Area Approvals

  • ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC

Product Safety

  • CE, C-tick

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103
show more