Proline T-Mass F 500 Thermal Mass Flowmeter

Brand: Endress+Hauser

Proline T-Mass F 500 Thermal Mass Flowmeter

Brand: Endress+Hauser
Extended Extended
Heartbeat Technology Heartbeat Technology

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement
  • Measurement of utility and process gases as well as gas mixtures in small line sizes

Device properties

  • Inline version with DN 15 to 100 (1/2 to 4")
  • Bidirectional measurement; high measuring performance
  • Patented drift-free sensor with SIL 2
  • Remote version with up to 4 I/Os
  • Backlit display with touch control and WLAN access
  • Standard cable between sensor and transmitter
Features
  • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
  • High level of process control – premium measurement accuracy and repeatability
  • Reliable monitoring – detection of process disturbances and reverse flow
  • Easy maintenance – removable sensor
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Thermal

Product Headline

  • Inline flowmeter with long-term stability as remote version with up to 4 I/Os
  • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
  • Measurement of utility and process gases as well as gas mixtures in small line sizes

Sensor Features

  • High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor
  • Inline version with DN 15 to 100 (1/2 to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology
  • Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter

Nominal Diameter Range

  • DN 15 to DN 100 (1/2" to 4")

Wetted Materials

  • Measuring tubes - DN 15 to 50 (1/2 to 2"): stainless cast steel, CF3M/1.4408
  • Measuring tubes - DN 65 to 100 (2-1/2 to 4"): stainless steel, 1.4404 (316/316L)
  • Process connections - flange connection: Stainless steel, 1.4404 (F316/F316L)
  • Process connections - thread connection: Stainless steel, 1.4404 (316/316L)
  • Sensing element - unidirectional: Stainless steel, 1.4404 (316/316L)
  • Sensing element - unidirectional: Alloy C22, 2.4602 (UNS N06022);
  • Sensing element - bidirectional: Stainless steel, 1.4404 (316/316L)
  • Reverse flow detection: Stainless steel, 1.4404 (316/316L)

Measured Variables

  • Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density

Max. Measurement Error

  • Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring Range

  • 0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Max. Process Pressure

  • PN40 / Cl. 300 / 20K

Medium Temperature Range

  • -40 °C to +180°C (-40 °F to +356 °F)

Ambient Temperature

  • -40 to 60°C (-40 to 140°F)
  • Transmitter: -50 to 60°C (-50 to 140°F), optional
  • Sensor: -60 to 60°C (-60 to 140°F), optional

Transmitter Housing Material

  • Aluminium, AlSi10Mg, coated
  • Polycarbonate

Degree of Protection

  • IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible

Outputs

  • 4 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, Modbus RS485

Power Supply

  • DC 24V
  • AC 100 to 240V

Hazardous Area Approvals

  • ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC

Product Safety

  • CE, C-tick

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103
show more