iTHERM ModuLine TM151 Industrial Modular Thermometer

Brand: Endress+Hauser

iTHERM ModuLine TM151 Industrial Modular Thermometer

Brand: Endress+Hauser
Extended Extended

Modular industrial RTD or TC thermometer, complete with barstock thermowell or to be used with onsite thermowell. Available with Endress+Hauser temperature transmitters for enhanced accuracy and reliability - easy customizing by choosing the outputs and communication protocols. Optionally available with Bluetooth® connectivity. Thermometer featuring latest innovations such as iTHERM QuickNeck , and temperature sensor technologies like iTHERM QuickSens and iTHERM StrongSens .

  • Universal range of application
  • Measuring range: –200 to +1.100 °C (–328 to +2.012 °F)
  • Pressure range up to 500 bar (7.252 psi)
  • Vibration-resistant sensor element up to 60g
  • Improved ease of maintenance (sensor replacement without process shutdown), easy and safe recalibration of the measuring point
Features
  • Second process seal with failure indication offering valuable device health status information
  • iTHERM QuickSens: fastest response times of 1.5 s for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
  • iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibration
  • Bluetooth® connectivity (optional)
  • International certification: explosion protection according to ATEX, IECEx, CSA C/US and CCC

Specifications

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • metric style
  • modular temperature assembly
  • universal range of application
  • suitable for hazardous areas
  • suitable for high process pressures
  • with neck or iTHERM QuickNeck
  • incl. thermowell / protection tube (metal) or to be installed into thermowell
  • can be used with iTHERM StrongSens

Thermowell / Protection Tube

  • barstock (drilled) or to be used with thermowell

Insert / Probe

  • mineral insulated (MI), flexible

Outer Diameter Protection Tube / Insert

  • 16 mm (0.63")
  • 18 mm (0.71")
  • 19 mm (0.75")
  • 19.5 mm (0.77")
  • 20 mm (0.79")
  • 22.2 mm (0.87")
  • 24 mm (0.95")
  • 25 mm (0.98")
  • 25.4 mm (1.0")
  • 26 mm (1.02")
  • 27 mm (1.06")
  • 30 mm (1.18")
  • 33.4 mm (1.31")

Max. Immersion Length on Request

  • up to 1.500 mm (59.06'')

Material Protection Tube/ Thermowell

  • 316 (1.4401)
  • 316L (1.4404)
  • 316/316L (1.4401/1.4404)
  • 316Ti (1.4571)
  • 347 (1.4550)
  • 310 (1.4841)
  • Alloy 600 (2.4816)
  • Alloy C276 (2.4819)
  • 10CrMo9-10 (1.7380)
  • 13CrMo4-5 (1.7335)
  • 16Mo3 (1.5415)
  • A105 (1.0460)
  • C22.8 (P250GH) (1.0460)
  • P355NH (1.0565)
  • Duplex S32205 (1.4462)
  • Titanium Gr2 (3.7035)

Process Connection

  • Male thread: G1", NPT1/2", NPT3/4", NPT 1", M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
  • Female thread: M24x1.5, NPT1/2"
  • Flange: DN25 PN16, PN40, PN50, PN100 B1; DN40 PN40 B1; DN50 PN40, PN63 B1; ASME 1" 150 RF, ASME 1" 300 RF, ASME 1" 600 RF, ASME 1" 900/1500 RF, ASME 1-1/2" 150 RF, ASME 1-1/2" 300 RF, ASME 1-1/2" 600 RF, ASME 1-1/2" 900/1500 RF, ASME 1-1/2" 2500 RF, ASME 2" 150 RF, ASME 2" 300 RF, ASME 2" 600 RF, ASME 2" 900/1500 RF, ASME 2" 2500 RF
  • To weld-in: Diameter 18 mm (0.71"), Diameter 24 mm (0.94"), Diameter 26 mm (1.02"), Diameter 26.7 mm (NPS 3/4"), Diameter 33.4 mm (NPS 1")

Tip shape

  • straight
  • tapered
  • stepped

Surface roughness Ra

  • 0.76 μm (30 μin.)
  • 1.6 μm (63.0 μin.)

Operating temperature range

  • PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F)
  • PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F)
  • PT100 WW: -200 °C ...600 °C (-328 °F ...1,112 °F)
  • PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F)
  • Typ K: max. 1,100 °C (max. 2,012 °F)
  • Typ J: max. 800 °C (max. 1,472 °F)
  • Typ N: max. 1,100 °C (max. 2,012 °F)

Max. Process Pressure (static)

  • depending on the configuration up to 500 bar

Accuracy

  • Class AA acc. to IEC 60751
  • Class A acc. to IEC 60751
  • Class B acc. to IEC 60751
  • Class special or standard acc. to ASTM E230
  • Class 1 or 2 acc. to IEC 60584-2

Response Time

  • depending on configuration

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex ec, Ex tc
  • ATEX IECEx Ex ia
  • NEPSI Ex ia

Certification

  • SIL, MID, DNV/GL
show more