iTHERM ModuLine TM151 Industrial Modular Thermometer

Brand: Endress+Hauser

iTHERM ModuLine TM151 Industrial Modular Thermometer

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended

Modular industrial RTD or TC thermometer, complete with barstock thermowell or to be used with onsite thermowell. Available with Endress+Hauser temperature transmitters for enhanced accuracy and reliability - easy customizing by choosing the outputs and communication protocols. Optionally available with Bluetooth® connectivity. Thermometer featuring latest innovations such as iTHERM QuickNeck , and temperature sensor technologies like iTHERM QuickSens and iTHERM StrongSens .

  • Universal range of application
  • Measuring range: –200 to +1.100 °C (–328 to +2.012 °F)
  • Pressure range up to 500 bar (7.252 psi)
  • Vibration-resistant sensor element up to 60g
  • Improved ease of maintenance (sensor replacement without process shutdown), easy and safe recalibration of the measuring point
Features
  • Second process seal with failure indication offering valuable device health status information
  • iTHERM QuickSens: fastest response times of 1.5 s for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
  • iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibration
  • Bluetooth® connectivity (optional)
  • International certification: explosion protection according to ATEX, IECEx, CSA C/US and CCC

Specifications

Product Family

  • iTHERM ModuLine

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • metric style
  • modular temperature assembly
  • universal range of application
  • suitable for hazardous areas
  • suitable for high process pressures
  • with neck or iTHERM QuickNeck
  • incl. thermowell / protection tube (metal) or to be installed into thermowell
  • can be used with iTHERM StrongSens

Thermowell / Protection Tube

  • barstock (drilled) or to be used with thermowell

Insert / Probe

  • mineral insulated (MI), flexible

Outer Diameter Protection Tube / Insert

  • 16 mm (0.63")
  • 18 mm (0.71")
  • 19 mm (0.75")
  • 19.5 mm (0.77")
  • 20 mm (0.79")
  • 22.2 mm (0.87")
  • 24 mm (0.95")
  • 25 mm (0.98")
  • 25.4 mm (1.0")
  • 26 mm (1.02")
  • 27 mm (1.06")
  • 30 mm (1.18")
  • 33.4 mm (1.31")

Max. Immersion Length on Request

  • up to 1.500 mm (59.06'')

Material Protection Tube/ Thermowell

  • 316 (1.4401)
  • 316L (1.4404)
  • 316/316L (1.4401/1.4404)
  • 316Ti (1.4571)
  • 347 (1.4550)
  • 310 (1.4841)
  • Alloy 600 (2.4816)
  • Alloy C276 (2.4819)
  • 10CrMo9-10 (1.7380)
  • 13CrMo4-5 (1.7335)
  • 16Mo3 (1.5415)
  • A105 (1.0460)
  • C22.8 (P250GH) (1.0460)
  • P355NH (1.0565)
  • Duplex S32205 (1.4462)
  • Titanium Gr2 (3.7035)

Process Connection

  • Male thread: G1", NPT1/2", NPT3/4", NPT 1", M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
  • Female thread: M24x1.5, NPT1/2"
  • Flange: DN25 PN16, PN40, PN50, PN100 B1; DN40 PN40 B1; DN50 PN40, PN63 B1; ASME 1" 150 RF, ASME 1" 300 RF, ASME 1" 600 RF, ASME 1" 900/1500 RF, ASME 1-1/2" 150 RF, ASME 1-1/2" 300 RF, ASME 1-1/2" 600 RF, ASME 1-1/2" 900/1500 RF, ASME 1-1/2" 2500 RF, ASME 2" 150 RF, ASME 2" 300 RF, ASME 2" 600 RF, ASME 2" 900/1500 RF, ASME 2" 2500 RF
  • To weld-in: Diameter 18 mm (0.71"), Diameter 24 mm (0.94"), Diameter 26 mm (1.02"), Diameter 26.7 mm (NPS 3/4"), Diameter 33.4 mm (NPS 1")

Tip shape

  • straight
  • tapered
  • stepped

Surface roughness Ra

  • 0.76 μm (30 μin.)
  • 1.6 μm (63.0 μin.)

Operating temperature range

  • PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F)
  • PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F)
  • PT100 WW: -200 °C ...600 °C (-328 °F ...1,112 °F)
  • PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F)
  • Typ K: max. 1,100 °C (max. 2,012 °F)
  • Typ J: max. 800 °C (max. 1,472 °F)
  • Typ N: max. 1,100 °C (max. 2,012 °F)

Max. Process Pressure (static)

  • depending on the configuration up to 500 bar

Accuracy

  • Class AA acc. to IEC 60751
  • Class A acc. to IEC 60751
  • Class B acc. to IEC 60751
  • Class special or standard acc. to ASTM E230
  • Class 1 or 2 acc. to IEC 60584-2

Response Time

  • depending on configuration

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex ec, Ex tc
  • ATEX IECEx Ex ia
  • NEPSI Ex ia

Certification

  • SIL, MID, DNV/GL
show more