Hydrostatic Level Measurement Deltapilot FMB52

Brand: Endress+Hauser

Hydrostatic Level Measurement Deltapilot FMB52

Brand: Endress+Hauser
Lean Lean

The Deltapilot FMB52 is a cable version including a fixed process connection. This device with the Contite measuring cell is typically used in the process and environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

For level measurement.

  • Process connections: Threads and flanges
  • Temperature: With PE cable: -10 to +70°C (+14 to +158°F),with FEP cable: -10 to +80°C (14 to 176°F)
  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)
  • Accuracy: ±0.2%, ±0.1% (option)
  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval
Features
  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
  • Modular concept for easy replacement of display or electronics
  • Seamless and independent system integration (HART/PA/FF)
  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
  • International usage thanks to a wide range of approvals

Specifications

Measuring Principle

  • Hydrostatic pressure

Characteristic

  • Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
  • Cable version

Supply Voltage

  • 4...20 mA HART
  • 10.5...45 VDC (Non Ex): Ex ia: 10.5...30 VDC
  • PROFIBUS PA: 9...32 VDC (Non Ex)
  • FOUNDATION Fieldbus: 9...32 VDC (Non Ex)

Reference Accuracy

  • Standard 0.2%
  • Optional 0.1%

Long Term Stability

  • 0.05 % of URL/year

Process Temperature

  • PE cable: -10°C…70°C (14°F…158°F)
  • FEP cable: -10°C…80°C (14°F…176°F)

Ambient Temperature

  • -40°C...85°C
  • (-40°F...185°F)

Measuring Cell

  • 100 mbar...10 bar
  • (1.5 psi...150 psi)

Smallest Calibratable Span

  • 10 mbar (1.45 psi)

Vacuum Resistance

  • 0 mbar abs.

Max. Turn Down

  • 100:1

Max. Overpressure Limit

  • 40 bar (600 psi)

Process Connection

  • Flange: DN40...DN100, ASME 2"...4", JIS 10K
  • Thread: G1-1/2, MNPT1-1/2

Material Process Membrane

  • 316L, AlloyC
  • Gold-Rhodium
  • PE, FEP

Material Gasket

  • Viton, EPDM, Kalrez, none

Fill fluid

  • Inert oil
  • Synthetic oil

Material Housing

  • 316L, Die-cast aluminum

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety Approvals

  • Overfill protection WHG
  • SIL

Design Approvals

  • EN10204-3.1
  • NACE MR0175

Marine Approvals

  • GL/ ABS/ LR/ BV/ DNV

Drinking Water Approvals

  • KTW/ NSF/ ACS

Specialities

  • Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
  • Diagnostic functions
show more