Hydrostatic Level Measurement Deltapilot FMB52

Brand: Endress+Hauser

Hydrostatic Level Measurement Deltapilot FMB52

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Lean Lean

The Deltapilot FMB52 is a cable version including a fixed process connection. This device with the Contite measuring cell is typically used in the process and environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. for use in SIL2 safety systems.

For level measurement.

  • Process connections: Threads and flanges
  • Temperature: with PE cable: -10 to +70°C (+14 to +158°F),with FEP cable: -10 to +80°C (14 to 176°F)
  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)
  • Accuracy: ±0.2%, ±0.1% (option)
  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval
Features
  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
  • Modular concept for easy replacement of display or electronics
  • Seamless and independent system integration (HART/PA/FF)
  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
  • International usage thanks to a wide range of approvals

Specifications

Product Family

  • Deltapilot

Measuring Principle

  • Hydrostatic Pressure

Characteristic

  • Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
  • Cable version

Supply Voltage

  • 4...20 mA HART
  • 10.5...45 VDC (Non Ex): Ex ia: 10.5...30 VDC
  • PROFIBUS PA: 9...32 VDC (Non Ex)
  • FOUNDATION Fieldbus: 9...32 VDC (Non Ex)

Reference Accuracy

  • Standard 0.2%
  • Optional 0.1%

Long Term Stability

  • 0.05 % of URL/year

Process Temperature

  • PE cable: -10°C…70°C (14°F…158°F)
  • FEP cable: -10°C…80°C (14°F…176°F)

Ambient Temperature

  • -40°C...85°C
  • (-40°F...185°F)

Measuring Cell

  • 100 mbar...10 bar
  • (1.5 psi...150 psi)

Smallest Calibratable Span

  • 10 mbar (1.45 psi)

Vacuum Resistance

  • 0 mbar abs.

Max. Turn Down

  • 100:1

Max. Overpressure Limit

  • 40 bar (600 psi)

Process Connection

  • Flange: DN40...DN100, ASME 2"...4", JIS 10K
  • Thread: G1-1/2, MNPT1-1/2

Material Process Membrane

  • 316L, AlloyC
  • Gold-Rhodium
  • PE, FEP

Material Gasket

  • Viton, EPDM, Kalrez, none

Fill fluid

  • Inert oil
  • Synthetic oil

Material Housing

  • 316L, Die-cast aluminum

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety Approvals

  • Overfill protection WHG
  • SIL

Design Approvals

  • EN10204-3.1
  • NACE MR0175

Marine Approvals

  • GL/ ABS/ LR/ BV/ DNV

Drinking Water Approvals

  • KTW/ NSF/ ACS

Specialities

  • Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
  • Diagnostic functions
show more