The patented four-tube Promass X provides premium accuracy (0.05 %) for highest capacity and offers an outstanding performance in on- and offshore applications in the oil and gas industry. With its compact transmitter Promass X 300 offers a high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • For highest flow rates and outstanding performance in on/offshore applications in the oil and gas industry

Device properties

  • Nominal diameter: DN 300 to 400 (12 to 16")
  • Four-tube system with low pressure drop
  • Complete exterior design made of 1.4435 (316L)
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Features
  • Increased profit – single installation point providing premium accuracy for large quantities
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Coriolis

Product Headline

  • Highest capacity four-tube flowmeter with a compact, easily accessible transmitter
  • For highest flow rates and outstanding performance in on/offshore oil and gas applications

Sensor Features

  • Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs
  • Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L)

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology
  • Compact dual-compartment housing with up to 3 I/Os

Nominal Diameter Range

  • DN 300 to 400 (12 to 16")

Wetted Materials

  • Measuring tube: 1.4404 (316/316L)
  • Connection: 1.4404 (316/316L)

Measured Variables

  • Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration

Max. Measurement Error

  • Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.35 %
  • Density (liquid): ±0.0005 g/cm³

Measuring Range

  • 0 to 4100 t/h (0 to 4520 tn. sh./h)

Max. Process Pressure

  • PN 100, Class 600

Medium Temperature Range

  • –50 to +180 °C (–58 to +356 °F)

Ambient Temperature

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor Housing Material

  • 1.4404 (316L), highest corrosion resistance

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

Degree of Protection

  • IP66/67, type 4X enclosure

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available"

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product Safety

  • CE, C-tick, EAC marking

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
  • MI-002, PTB

Marine Approvals and Certificates

  • LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK