Ultrasonic Measurement Time-of-Flight Prosonic FDU95

Brand: Endress+Hauser

Ultrasonic Measurement Time-of-Flight Prosonic FDU95

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended

The FDU95 ultrasonic sensor is for continuous, non-contact, and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density, or humidity and also unaffected by buildup due to the self-cleaning effect of sensors. Suited for explosion-hazardous areas. Maximum measuring range in solids is 45m (148ft).

Sensor for continuous, non-contact level measurement of bulk materials in silos, on belts, stockpiles, and in crushers. Typically used in measurements in low structural heights.

  • Process connection: Thread
  • Temperature: -40 to +80°C or +150°C (-40 to +176°F or +302°F)
  • Pressure: +0.7 to +1.5bar (+10 to +22psi)
  • Maximum measuring range: Solids 45m (148ft)
  • Blocking distance: 0.7m / 80°C (2.3ft), 0.9m / 150°C (2.9ft)
  • International explosion protection certificates
Features
  • Integrated temperature sensor for time-of-flight correction. Accurate measurements are possible, even if temperature changes are present
  • Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
  • Reduced build-up formation because of the self-cleaning effect
  • Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
  • Weather resistant and flood-proof (IP 68)
  • Non-contact measurement method minimizes service requirements
  • International Dust-Ex and Gas-Ex certificates available

Specifications

Product Family

  • Prosonic

Measuring Principle

  • Ultrasonic

Characteristic / Application

  • Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

  • 4-wire (HART, PROFIBUS DP)

Accuracy

  • +/- 2 mm + 0.17% of measured distance

Ambient Temperature

  • -40 °C...80 °C or 150 °C
  • (-40 °F...176 °F or 302 °F)

Process Temperature

  • -40 °C...80 °C or 150 °C
  • (-40 °F...176 °F or 302 °F)

Process Pressure / Max. Overpressure Limit

  • 0.7 bar...1.5 bar abs
  • (10 psi...22 psi)

Main Wetted Parts

  • UP (unsaturated polyester)

Process Connection

  • G / NPT 1"

Blocking Distance

  • 0.7 m / 80 °C
  • (2.3 ft / 176 °F)
  • 0.9 m / 150 °C
  • (2.9 ft / 302 °F)

Max. Measurement Distance

  • 45 m (148 ft)

Communication - Transmitter

  • 4...20 mA HART
  • PROFIBUS DP

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI,UK Ex

Options

  • Second 4...20 mA output

Components

  • FMU90
  • FMU95