SS2100i Gas Analyzer

Brand: Endress+Hauser

SS2100i Gas Analyzer

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Xpert Xpert

SS2100i gas analyzers accurately measure trace gas components (H 2 O, CO 2 , H 2 S, NH 3 , and C 2 H 2 ) using tunable diode laser absorption spectroscopy (TDLAS) technology. The analyzers require little maintenance and do not need recalibration or periodic replacement parts. SS2100i gas analyzers are certified for ATEX/IECEx Zone 1.

  • Gas analysis: ppb level measurement of H2O & NH3, ppm level measurement of H2O, H2S, CO2, NH3, and C2H2, and % level measurement of H2S and CO2
  • Natural gas: production, storage, transportation, distribution
  • Refinery: hydrogen recycle, catalytic reforming, flaring, cracking
  • Gas processing: fractionation, sour/acid gas removal
  • LNG: liquefication, custody transfer
  • Petrochemical: cracking, acetylene converter, caustic wash tower
  • Biomethane: custody transfer measurements of CO2, H2S, H2O
Features
  • Accurate, real-time measurements not hampered by wet-up (absorption) or dry-down (desorption)
  • Virtually maintenance free and reliable in harsh environments
  • Dependable with greater repeatability than surface-based sensors with NIST-traceable calibration
  • Analog and serial outputs for remote monitoring
  • Low cost of ownership, no consumables
  • Available for the following measurements: H2O, CO2, H2S, NH3, C2H2
  • ATEX/IECEx Zone 1 certified

Specifications

Measuring Principle

  • TDLAS

Channels

  • 1

Analyte and Measurement Ranges

  • H2S (Hydrogen Sulfide):
  • 0 to 10 ppmv
  • 0 to 1000 ppmv
  • 0 to 5000 ppmv
  • 0 to 5% volume

Measured Variables

  • Concentration
  • Cell Pressure
  • Cell Temperature

Ambient Temperature

  • -20 to 50°C (-4 to 122°F)
  • Optional (i-2 only): -10 to 60°C (14 to 140°F)

Operating Pressure Range

  • Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
  • Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)

Analyzer Wetted Materials

  • 316L stainless steel
  • FKM O-Rings
  • Glass

Power Supply

  • 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W

Communication

  • Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
  • Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
  • Serial: RS232C and Ethernet
  • Protocol: Modbus Gould RTU or Daniel RTU or ASCII
  • Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
  • Digital Inputs: 2, Flow Alarm, Validation Request

Housing Materials

  • Electronics: Copper-free Aluminum
  • Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
  • Sample System Enclosure: 304 or 316 stainless steel

Hazardous Area Approvals

  • IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1

Degree of Protection

  • IP66

Product Safety

  • CE

Metrological Approvals

  • PAC China, Kazakhstan (i-1 only)
show more