TH51 Modular TC Thermometer, US Style
Brand: Endress+HauserTH51 Modular TC Thermometer, US Style
Brand: Endress+Hauser
The high modular thermometer is used for several applications in almost all industries. Examples are heat exchangers, furnaces, dryers, process reactors, etc. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability. It also enables very fast response times, due to direct contact measurement without thermowell. A variety of process connections and dimensions offer flexible application possibilities.
Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose applications.
The sensors can be used on:
- Heat exchangers
- Power & recovery areas
- Furnaces
- Dryers
- Flue gas
- Compressor stations
- Process reactors
- Metallurgical and glass manufacturing
- One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering. Remove and install straight out of the box!
- Improved galvanic isolation on most devices (2 kV)
- Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for acomplete point solution
- All iTEMP® transmitters provide long term stability ≤ 0.05 % per year
Specifications
Brand
Measuring Principle
- Thermocouple
Characteristic / Application
- US style
- modular temperature assembly
- threaded process connection
Thermowell / Protection Tube
- without (not intended to use with thermowell)
Insert / Probe
- mineral insulated (MI), flexible
Outer Diameter Protection Tube / Insert
- 1/8'' (3.18 mm)
- 3/16''(4.76 mm)
- 1/4'' (6.35 mm)
- 3/8'' (9.53 mm)
Max. Immersion Length on Request
- up to 96" (2,438 mm)
- others on request
Material Protection Tube/ Thermowell
- 316
- Alloy 600
Optional Coating
- Not applicable
Process Connection
- male thread: G1/2", NPT1/2"
- compression fitting: NPT1/8", NPT1/4"
Tip Shape
- straight
Surface Roughness Ra
- Not defined
Operating Temperature
- Type T: -270 °C ...400 °C (-454 °F ...752 °F)
- Type J: -210 °C ...1.200 °C (-346 °F ...2.192 °F)
- Type E: -270 °C ...1.000 °C (-454 °F ...1.832 °F)
- Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F)
- Type N: -270 °C ... 1.300 °C (-454 °F ...2.372 °F)
Max. Process Pressure (static)
- at 20°C: 250 bar (3.626 psi)
- depends on configuration
Accuracy
- Standard acc. to ASTM E-230
- Special acc. to ASTM E-230
Response Time
- 63% rt = 0.3 s
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - Approvals
- transmitter only
- FM IS
- CSA IS
- FM/CSA IS
Certification
- SIL (transmitter only)