Proline T-Mass T 150 Thermal Mass Flowmeter

Brand: Endress+Hauser

Proline T-Mass T 150 Thermal Mass Flowmeter

Brand: Endress+Hauser

The t-mass T 150 is the first thermal mass device from Endress+Hauser for measuring liquids. t-mass T 150 is designed chiefly for water applications. As it measures independently of the electrical conductivity of a fluid and can be used in a variety of water-based and non-water-based liquids for the purpose of monitoring and trending. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement
  • Dedicated to the monitoring of conductive and non-conductive liquids

Device properties

  • Insertion version for nominal diameter DN 40 to 1000 (1 1/2 to 40")
  • Sensor in standard or hygienic version
  • SIP cleaning possible up to 130 °C (266 °F)
  • Device in compact version with DC 24 V power supply
  • 4-20 mA HART, pulse/frequency/switch output
  • Compact and robust transmitter
Features
  • Dedicated to the monitoring of conductive and non-conductive liquids
  • High process safety – high repeatability and linearity due to integrated temperature compensation
  • Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
  • Reliable flow trending – multivariable measurement
  • Fast and efficient commissioning – guided operating menus
  • High plant availability – self-diagnostics and error monitoring
  • Automatic recovery of data for servicing

Specifications

Measuring Principle

  • Thermal

Product Headline

  • The flowmeter for reliable and easy monitoring of liquids. Dedicated to the monitoring of conductive and non‐conductive liquids

Sensor Features

  • High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1-1/2 to 40"). Sensor in standard or hygienic version

Transmitter Features

  • Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output

Nominal Diameter Range

  • DN 40 to 1000 (1-1/2 to 40")

Wetted Materials

  • Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
  • Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
  • Connection ‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
  • Connection ‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
  • Connection ‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
  • Connection ‐ Tri‐Clamp: DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)

Measured Variables

  • Mass flow, temperature, volume flow

Max. Measurement Error

  • Flow: ±5 % o.f.s.

Measuring Range

  • 226 to 14,100,000 l/h (60 to 3,730,000 gal/h) (under reference conditions)

Max. Process Pressure

  • PN 40

Medium Temperature Range

  • –20 to +100 °C (–4 to +212 °F)

Ambient Temperature

  • –40 to +60 °C (–40 to +140 °F)

Transmitter Housing Material

  • AlSi10Mg, coated

Degree of Protection

  • IP66/67, type 4X enclosure

Display/Operation

  • 4‐line display with push buttons
  • Configuration via local display and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • Status input

Digital Communication

  • HART

Power Supply

  • DC 18 to 30 V

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus

Other Approvals and Certificates

  • 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Hygienic approvals: EHEDG, 3-A

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

Pressure Approvals and Certificates

  • CRN

Material Certificates

  • 3.1 material

Hygienic Approvals and Certificates

  • Sanitary approval: 3-A, EHEDG
show more