LNGmass Coriolis Flowmeter
Brand: Endress+HauserLNGmass Coriolis Flowmeter
Brand: Endress+HauserLNGmass is a Coriolis flowmeter specifically developed for dispensers, guaranteeing highest accuracy and robustness at extreme subzero temperatures down to –196 °C (–321 °F). Due to the most compact design worldwide, the device can be installed anywhere, even in the narrowest space conditions without any problem. The LNGmass has no moving parts and is, therefore, absolutely maintenance-free.
- Measuring principle operates independently of physical fluid properties such as viscosity or density
- Accurate measurement of cryogenic gases in refueling applications
Device properties
- Flow rates up to 18 000 kg/h (660 lb/min)
- Medium temperature down to –196 °C (–321 °F)
- Nominal diameter: DN 8 to 25 (3/8 to 1")
- Robust, compact transmitter housing
- Modbus RS485
- Designed to meet application needs
- Excellent operational safety – reliable under extreme ambient conditions
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in/outlet run needs
- Space-saving transmitter – full functionality on the smallest footprint
- Fast commissioning – pre-configured devices
- Automatic recovery of data for servicing
Specifications
Brand
Measuring Principle
- Coriolis
Product Headline
- Refueling application flowmeter with easy system integration. Accurate measurement of cryogenic gases in refueling applications
Sensor Features
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in/outlet run needs
- Flow rates up to 18 000 kg/h (660 lb/min)
- Medium temperature down to –196 °C (–321 °F)
- Excellent operational safety – reliable under extreme ambient conditions
Transmitter Features
- Fast commissioning – pre‐configured devices
- Automatic recovery of data for servicing
- Robust, compact transmitter housing. Modbus RS485
- Space‐saving transmitter – full functionality on the smallest footprint
Nominal Diameter Range
- DN 8 to 25 (3/8 to 1")
Wetted Materials
- Measuring tubes: 1.4539 (904L)
- Connection: 1.4404 (316/316L)
Measured Variables
- Mass flow, density, temperature, volume flow, corrected volume flow
Max. Measurement Error
- Mass flow (liquid): ±0.15 %
- Volume flow (liquid): ±0.15 %
- (Reference condition)
Measuring Range
- 0 to 18 000 kg/h (0 to 660 lb/min)
Max. Process Pressure
- PN 40, Class 300
Medium Temperature Range
- –196 to +125 °C (–320 to +257 °F)
Ambient Temperature
- –40 to +60 °C (–40 to +140 °F)
Sensor Housing Material
- 1.4301 (304), corrosion resistant
Transmitter Housing Material
- AlSi10Mg, coated
Degree of Protection
- IP66/67, type 4X enclosure
Display/Operation
- No local operation
- Configuration via operating tools possible
Outputs
- None
Inputs
- None
Digital Communication
- Modbus RS485
Power Supply
- DC 20 to 30 V
Hazardous Area Approvals
- ATEX, IECEx, cCSAus, NEPSI, EAC
Other Approvals and Certificates
- 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- CRN
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Material Certificates
- 3.1 material