Capacitance Point Level Detection Minicap FTC260

Brand: Endress+Hauser

Capacitance Point Level Detection Minicap FTC260

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Fundamental Fundamental

Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up.

It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.

  • Process connection: Threads
  • Temperature: -40 to +80 °C (-40 to +176 °F)
  • Pressure: -1 to +25 bar (-14.5 to +360 psi)
  • Sensor length: 140 mm (5.51")
  • International explosion protection certificates, overfill prevention WHG
Features
  • Simple mounting and commissioning without calibration
  • Mechanical safety, cost-efficiency and long operating life due to no wearing parts
  • High operational safety and reliability due to active build-up compensation

Specifications

Product Family

  • Minicap

Measuring Principle

  • Capacitive Solid

Characteristic / Application

  • Compact rod probe with build-up compensation easy start up

Specialities

  • FDA-listed material

Supply / Communication

  • 10.8 ... 45 VDC, DC-PNP 3-wire
  • 20 ... 253 VAC
  • 20 ... 55 VDC, Relay output

Ambient Temperature

  • -40... +70 °C (-40... +158 °F)

Process Temperature

  • -40... +120 °C (-40... +248 °F)

Process Pressure / Max. Overpressure Limit

  • -1 ... 25 bar (-14.5 ... 360 psi)

Main Wetted Parts

  • PPS = Polyphenylene sulphide (glass fibre content approx. 40%)

Process Connection

  • R1"
  • NPT1"

Sensor Length

  • 140 mm (5.51")

Communication

  • PNP transistor output
  • Relay output (potential-free change-over contact / SPDT)

Certificates / Approvals

  • ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex

Options

  • Aluminium Housing

Application Limits

  • Solids, grain size max. 30 mm (1.2"), Dk min 1.6
  • Flexural strength 1,400 N (at probe tip)
show more