Proline Promass A 200 Coriolis Flowmeter

Brand: Endress+Hauser

Proline Promass A 200 Coriolis Flowmeter

Brand: Endress+Hauser
Extended Extended
Heartbeat Technology Heartbeat Technology

The compact Promass A is ideal for continuous process control in demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its cost-effective genuine loop-powered technology and intrinsically safe design (Ex ia), Promass A 200 offers highest operational safety in hazardous areas. Heartbeat Technology enables safe processes.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Suitable for applications with smallest flow quantities in the chemical industry

Device properties

  • Nominal diameter: DN 1 to 4 (1/24 to 1/8")
  • Process pressure up to 430.9 bar (6250 psi)
  • Medium temperature up to +205 °C (+401 °F)
  • Loop-powered technology
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Features
  • Space-saving installation – compact, lightweight sensor
  • Highest product quality – self-drainable measuring tube design in all line sizes
  • Optimum process safety – resistant to corrosive ambient conditions and internal clogging
  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Coriolis

Product Headline

  • Genuine loop-powered flowmeter for accurate measurement of lowest flow rates
  • Suitable for applications with smallest flow quantities in the chemical industry

Sensor Features

  • Space-saving installation – compact, lightweight sensor
  • Highest product quality – self-drainable measuring tube design in all line sizes
  • Optimum process safety – resistant to corrosive ambient conditions and internal clogging
  • Nominal diameter: DN 1 to 4 (1/24 to 1/8"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F)

Transmitter Features

  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat Technology
  • Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

Nominal Diameter Range

  • DN 1 to 4 (1/24 to 1/8")

Wetted Materials

  • Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22

Measured Variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Max. Measurement Error

  • Mass flow (liquid): ±0.1 %
  • Volume flow (liquid): ±0.1 %
  • Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³

Measuring Range

  • 0 to 450 kg/h (0 to 16.54 lb/min)

Max. Process Pressure

  • 430.9 bar (6250 psi)

Medium Temperature Range

  • -50 to 205 °C (-58 to 401 °F)

Ambient Temperature

  • -40 to 60 °C (-40 to +140 °F)

Sensor Housing Material

  • Stainless steel, 1.4404 (316L)

Transmitter Housing Material

  • Stainless steel, CF-3M (316L, 1.4404)
  • AlSi10MG, coated

Degree of Protection

  • IP66/67, Type 4X enclosure

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 4‐20 mA HART (passive)
  • 4‐20 mA (passive)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital Communication

  • HART, PROFIBUS PA, FOUNDATION Fieldbus

Power Supply

  • DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
  • DC 18 to 30 V (20 mA HART, 4‐20 mA)
  • DC 9 to 32 V (PROFIBUS PA)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex

Product Safety

  • CE, C-TICK

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure Approvals and Certificates

  • CRN

Material Certificates

  • 3.1 material

Hygienic Approvals and Certificates

  • 3-A, cGMP
show more