Proline Promass F 200 Coriolis Flowmeter
Brand: Endress+HauserProline Promass F 200 Coriolis Flowmeter
Brand: Endress+Hauser

Promass F has a long standing reputation as a highly accurate device. It is suited for broadest range of applications. Promass F 200 offers in addition genuine, industry-compliant two-wire technology. This enables seamless system integration into existing infrastructures. Additional advantages are high operational safety in hazardous areas thanks to an intrinsically safe design (Ex ia) and process safety at all times enabled by Heartbeat Technology.
- Measuring principle operates independently of physical fluid properties such as viscosity or density
- Highest measurement performance for liquids and gases in a wide range of applications
Device properties
- Mass flow: measured error ±0.1 %
- Medium temperature up to +205 °C (+401 °F)
- Nominal diameter: DN 8 to 80 (3/8 to 3")
- Loop-powered technology
- Robust dual-compartment housing
- Plant safety: worldwide approvals (SIL, Haz. area)
- Highest process safety – immune to fluctuating and harsh environments
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in/outlet run needs
- Convenient device wiring – separate connection compartment
- Safe operation – no need to open the device due to display with touch control, background lighting
- Integrated verification – Heartbeat Technology
Specifications
Brand
Measuring Principle
- Coriolis
Product Headline
- Robust flowmeter with genuine loop-powered technology
- Highest measurement performance for liquids and gases in a wide range of applications
Sensor Features
- Highest process safety – immune to fluctuating and harsh environments
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space‐saving installation – no in-/outlet run needs
- Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (3/8 to 3")
Transmitter Features
- Convenient device wiring – separate connection compartment
- Safe operation – no need to open the device due to display with touch control, background lighting
- Integrated verification – Heartbeat Technology
- Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area)
Nominal Diameter Range
- DN 8 to 80 (3/8 to 3")
Wetted Materials
- Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022)
- Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured Variables
- Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. Measurement Error
- Mass flow (liquid): ±0.1 %
- Volume flow (liquid): ±0.1 %
- Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
Measuring Range
- 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. Process Pressure
- PN 100, Class 600, 63K
Medium Temperature Range
- Standard: –50 to +150 °C (–58 to +302 °F)
- Option: –50 to +205 °C (–58 to +401 °F)
Ambient Temperature
- –40 to +60 °C (–40 to +140 °F)
Sensor Housing Material
- 1.4301/1.4307 (304L), corrosion resistant
Transmitter Housing Material
- AlSi10Mg, coated, 1.4404 (316L)
Degree of Protection
- IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- None
Digital Communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply
- DC 18 to 35 V (4‐20 mA HART with/without
- pulse/frequency/switch)
- DC 18 to 30 V (20 mA HART, 4‐20 mA)
- DC 9 to 32 V (PROFIBUS PA)
Hazardous Area Approvals
- ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product Safety
- CE, C-TICK
Functional Safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure Approvals and Certificates
- PED, CRN, AD 2000
Material Certificates
- 3.1 material
- NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic Approvals and Certificates
- 3-A, EHEDG, cGMP