Proline Prosonic Flow 92F Ultrasonic Flowmeter
Brand: Endress+HauserProline Prosonic Flow 92F Ultrasonic Flowmeter
Brand: Endress+Hauser
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
- The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
- Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
- Full compliance according to NACE MR0175 and MR0103
- Nominal diameter: DN 25 to 300 (1 to 12")
- Medium temperature: –40 to 200 °C (–40 to 392 °F)
- Device as compact or remote version
- 2-line backlit display with push buttons
- HART, PROFIBUS PA, FOUNDATION Fieldbus
- Safe design for process industries – international hazardous area approvals
- No additional pressure loss – full-bore design
- Process transparency – diagnostic capability
- Easy installation and reduced installation costs – loop-powered transmitter
- Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
- Automatic recovery of data for servicing
Specifications
Brand
Measuring Principle
- Ultrasonic flow
Product Headline
- Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs
- Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Sensor Features
- Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability
- Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F)
Transmitter Features
- Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing
- Device as compact or remote version. 2-line backlit display with push buttons. HART
Nominal Diameter Range
- 2 path version: DN80 to 300 (3 to12")
- 3 path version: DN25 to 50 (1 to 2")
- 4 path version: DN 80 to 300 (3 to 12")
Wetted Materials
- Sensor: A351-CF3M (DN25 to 100), 1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
- Transducer: 1.4404/316/316L
- Flanges: 1.4404/316/316L or A105/1.0432
Measured Variables
- Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength
Max. Measurement Error
- Volume flow (standard): ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- Volume flow (option): ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Measuring Range
- 0.5 to 10 m/s (1.6 to 33 ft/s)
Max. Process Pressure
- PN 40 / ASME Cl. 300 / JIS 20K
Medium Temperature Range
- -40 to +150 °C (-40 to +302 °F)
- -40 to +200 °C (-40 to +392 °F) optional
Ambient Temperature
- -40 to +60 °C (-40 to +140 °F) compact
- -40 to +80 °C (-40 to +176 °F) remote sensor
- -40 to +60 °C (-40 to +140 °F) remote transmitter
Transmitter Housing Material
- AlSi10Mg, coated
Degree of Protection
- IP67, type 4X enclosure
- IP68 type 6P enclosure (option for remote)
Display/Operation
- 2 lines backlit display with 3 push buttons
Outputs
- 1x 4-20 mA HART
- 1x Pulse/frequency/switch output (passive)
Digital Communication
- HART
Power Supply
- 2 wire loop powered
Hazardous Area Approvals
- ATEX,FM, CSA, JPNm UK Ex
Other Approvals and Certificates
- 3.1 material (wetted parts), calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
- PED, EAC marking
Product Safety
- EAC marking
Metrological Approvals and Certificates
- calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure Approvals and Certificates
- CRN, PED, AD2000
Material Certificates
- 3.1 material (wetted parts)