Proline Prosonic Flow 92F Ultrasonic Flowmeter

Brand: Endress+Hauser

Proline Prosonic Flow 92F Ultrasonic Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended

Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.

  • The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
  • Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

Device properties:

  • Full compliance according to NACE MR0175 and MR0103
  • Nominal diameter: DN 25 to 300 (1 to 12")
  • Medium temperature: –40 to 200 °C (–40 to 392 °F)
  • Device as compact or remote version
  • 2-line backlit display with push buttons
  • HART, PROFIBUS PA, FOUNDATION Fieldbus
Features
  • Safe design for process industries – international hazardous area approvals
  • No additional pressure loss – full-bore design
  • Process transparency – diagnostic capability
  • Easy installation and reduced installation costs – loop-powered transmitter
  • Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
  • Automatic recovery of data for servicing

Specifications

Product Family

  • Prosonic

Measuring Principle

  • Ultrasonic Flow

Product Headline

  • Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs
  • Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

Sensor Features

  • Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability
  • Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F)

Transmitter Features

  • Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing
  • Device as compact or remote version. 2-line backlit display with push buttons. HART

Nominal Diameter Range

  • 2 path version: DN80 to 300 (3 to12")
  • 3 path version: DN25 to 50 (1 to 2")
  • 4 path version: DN 80 to 300 (3 to 12")

Wetted Materials

  • Sensor: A351-CF3M (DN25 to 100), 1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
  • Transducer: 1.4404/316/316L
  • Flanges: 1.4404/316/316L or A105/1.0432

Measured Variables

  • Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength

Max. Measurement Error

  • Volume flow (standard): ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
  • Volume flow (option): ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

Measuring Range

  • 0.5 to 10 m/s (1.6 to 33 ft/s)

Max. Process Pressure

  • PN 40 / ASME Cl. 300 / JIS 20K

Medium Temperature Range

  • -40 to +150 °C (-40 to +302 °F)
  • -40 to +200 °C (-40 to +392 °F) optional

Ambient Temperature

  • -40 to +60 °C (-40 to +140 °F) compact
  • -40 to +80 °C (-40 to +176 °F) remote sensor
  • -40 to +60 °C (-40 to +140 °F) remote transmitter

Transmitter Housing Material

  • AlSi10Mg, coated

Degree of Protection

  • IP67, type 4X enclosure
  • IP68 type 6P enclosure (option for remote)

Display/Operation

  • 2 lines backlit display with 3 push buttons

Outputs

  • 1x 4-20 mA HART
  • 1x Pulse/frequency/switch output (passive)

Digital Communication

  • HART

Power Supply

  • 2 wire loop powered

Hazardous Area Approvals

  • ATEX,FM, CSA, JPNm UK Ex

Other Approvals and Certificates

  • 3.1 material (wetted parts), calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
  • PED, EAC marking

Product Safety

  • EAC marking

Metrological Approvals and Certificates

  • calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Pressure Approvals and Certificates

  • CRN, PED, AD2000

Material Certificates

  • 3.1 material (wetted parts)
show more