iTHERM ModuLine TM131 Industrial Modular Thermometer

Brand: Endress+Hauser

iTHERM ModuLine TM131 Industrial Modular Thermometer

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended

Intrinsically safe temperature sensor (RTD / TC assembly) with manufactured thermowell or for use with existing thermowell. An optional head transmitter with all common communication protocols – Bluetooth® technology inclusive – and special features like iTHERM QuickNeck for tool-free, easy recalibration, vibration-resistant and fast-response sensor and thermowell technology ( iTHERM StrongSens , QuickSens ) as well as hazardous area approvals ensure enhanced measurement accuracy and reliability.

  • Universal range of application
  • Measuring range: –200 to +1,100 °C (–328 to +2,012 °F)
  • Pressure range up to 100 bar (1450 psi)
  • Degree of protection: up to IP 68
  • Vibration-resistant sensor elements up to 60g
  • Improved ease of maintenance (sensor replacement without process shutdown), easy and safe recalibration of the measuring point
Features
  • Second process barrier with failure indication offering valuable health status information
  • iTHERM QuickSens: fastest response times 1.5 s for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
  • iTHERM QuickNeck: cost and time savings thanks to simple, tool-free recalibration
  • Bluetooth® connectivity (optional)
  • International certification: explosion protection according to ATEX, IECEx, CSA C/US and NEPSI

Specifications

Product Family

  • iTHERM ModuLine

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • metric style
  • modular temperature assembly
  • universal range of application
  • suitable for hazardous areas
  • with neck or iTHERM QuickNeck
  • incl. thermowell / protection tube (metal) or to be installed into thermowell
  • can be used with iTHERM StrongSens, iTHERM QuickSens insert
  • for fast response times

Thermowell / Protection Tube

  • welded protection tube or to be used with thermowell

Insert / Probe

  • mineral insulated (MI), flexible

Outer Diameter Protection Tube / Insert

  • 9x1.25 mm
  • 11x2 mm
  • 12x2.5 mm
  • 14x2 mm
  • 16x3.5 mm
  • 1/4" SCH80
  • 1/2" SCH80
  • 1/2" SCH40

Max. Immersion Length on Request

  • up to 4500 mm (177'')

Material Protection Tube/ Thermowell

  • 316 (1.4401)
  • 316L (1.4404)
  • 316Ti (1.4571)
  • Alloy 600 (2.4816)
  • Alloy C276 (2.4819)
  • Alloy 446 (1.4749)
  • Alloy 321 (1.4541)
  • Sheath PTFE
  • Sheath Tantal

Process Connection

  • Male thread: G3/8", G1/2", G3/4", G1"; NPT1/2", NPT3/4", NPT 1"; M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2; R1/2", R3/4"
  • Female thread: M20x1.5, M24x1.5; NPT1/2"
  • Cap-nut: M20x1.5, G1/2", G3/4"
  • Compression fitting: NPT1/2", G1/2", G1"
  • Flange: DN15 PN40 B1, C; DN25 PN20, PN40, PN100 B1, B2, C; DN40 PN40 B1; DN50 PN40 B1; ASME 1" 150 RF, ASME 1" 300 RF, ASME 1 1/2" 150 RF, ASME 2" 150 RF, ASME 2" 300 RF

Tip Shape

  • straight
  • reduced
  • tapered
  • optimized for quick response times

Surface Roughness Ra

  • < 0.76 μm (0.03 μin)

Operating Temperature

  • PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F)
  • PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F)
  • PT100 WW: -200 °C ...600 °C (-328 °F ...1,112 °F)
  • PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F)
  • Typ K: max. 1,100 °C (max. 2,012 °F)
  • Typ J: max. 800 °C (max. 1,472 °F)
  • Typ N: max. 1,100 °C (max. 2,012 °F)

Max. Process Pressure (static)

  • depending on the configuration up to 100 bar

Accuracy

  • Class AA acc. to IEC 60751
  • Class A acc. to IEC 60751
  • Class B acc. to IEC 60751
  • Class special or standard acc. to ASTM E230
  • Class 1 or 2 acc. to IEC 60584-2

Response Time

  • fastest response time with thermowell t90 starting at below 10 s
  • depending on configuration

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex ec, Ex tc
  • ATEX IECEx Ex ta/tb, Ex ia, Ex db
  • CSA C/US IS, NI, XP, DIP
  • INMETRO Ex ia, Ex d, Ex tb
  • NEPSI Ex ia, Ex d, Ex tD
  • EAC Ex d, Ex ta/tb, Ex ia
  • UKCA Ex ia, Ex nA, Ex tc

Certification

  • SIL, MID, DNV/GL
show more