TA571 Barstock Thermowell
Brand: Endress+HauserTA571 Barstock Thermowell
Brand: Endress+Hauser
Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.
TA571 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.
Features- The extension, the immersion and the tapering lengths as well as the bar dimensions can be chosen according to process requirements
- A wide choice of standard materials is available; other versions can be ordered according to specification
- Different grades of surface finishing are also available
- The process connection is welded. The thermowell stem shape can be straight with a conical tip shape
Specifications
Brand
Measuring Principle
- Bar stock Thermowell
Characteristic / Application
- metric style
- weld-in process connections
- round extension
Head Connection
- internal thread: 1/2" NPT, 1/2" NPSM, G1/2"
Maximum Standard Immersion Length
- 1000 mm (39.37")
Max. Immersion Length on Request
- 5,000 mm (196.85")
Process Connection
- to weld-in
Thermowell Root Diameter
- 20 mm (0.79")
- 25.4 mm (1")
Medium Contact Material
- 1.4401 (316)
- 1.4404 (316L)
- 1.4571 (316Ti)
Wetted Part Finishing (Ra)
- < 0.8 μm (31.50 μin)
- < 1.6 μm (63.00 μin)
Tip Shape
- straight
- conical
- conical tapered
Temperature Range
- -200...700 °C (-328...1.292 °F)
Max. Process Pressure (static)
- 500 bar (7252 psi)
Max. Process Pressure at 400 °C
- 300 bar (4351 psi)