Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. With its compact transmitter Promass O 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables safe processes.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • For premium accuracy at highest process pressures, fully suitable for offshore conditions

Device properties

  • Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750)
  • Process pressure up to PN 250 (Class 1500)
  • Nominal diameter: DN 80 to 250 (3 to 10")
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Features
  • Maximum safety – highest resistance to stress corrosion cracking
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Coriolis

Product Headline

  • Robust high-pressure flowmeter with a compact, easily accessible transmitter
  • For premium accuracy at highest process pressures, fully suitable for offshore conditions

Sensor Features

  • Maximum safety – highest resistance to stress corrosion cracking
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space‐saving installation – no in-/outlet run needs
  • Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10")

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available

Nominal Diameter Range

  • DN 80 to 250 (3 to 10")

Wetted Materials

  • Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
  • Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)

Measured Variables

  • Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration

Max. Measurement Error

  • Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.35 %
  • Density (liquid): ±0.0005 g/cm³

Measuring Range

  • 0 to 2,200,000 kg/h (0 to 80,850 lb/min)

Max. Process Pressure

  • PN 250, Class 1500

Medium Temperature Range

  • –40 to +205 °C (–40 to +401 °F)

Ambient Temperature

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor Housing Material

  • 1.4404 (316L), highest corrosion resistance

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

Degree of Protection

  • IP66/67, type 4X enclosure

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product Safety

  • CE, C-tick, EAC marking

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
  • OIML R117 Liquids other than water, Cryogenic Liquids, LPG
  • MI-002, PTB

Marine Approvals and Certificates

  • LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure Approvals and Certificates

  • PED, CRN, AD 2000

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK