iTHERM CableLine TH56 Cable Probe

Brand: Endress+Hauser

iTHERM CableLine TH56 Cable Probe

Brand: Endress+Hauser
Fundamental Fundamental

The thermocouple sensor with plug connection is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is used in many process and laboratory applications such as heat exchangers, furnaces or dryers. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.

Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose applications.

The sensors can be used on:

  • Heat exchangers
  • Power & recovery areas
  • Furnaces
  • Dryers
  • Flue gas
  • Compressor stations
  • Process reactors
Features
  • Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solution
  • Improved galvanic isolation on most devices (2 kV)
  • One source shopping for temperature measurement solutions. Remove and install straight out of the box!
  • All iTEMP® transmitters provide long term stability ≤ 0.05 % per year

Specifications

Measuring Principle

  • Thermocouple

Characteristic / Application

  • Industrial US style
  • Cable probe
  • Process connection as compression fitting

Thermowell / Protection Tube

  • Without (not intended to use with thermowell)

Insert / Probe

  • Mineral insulated (MI), flexible

Outer Diameter Protection Tube / Insert

  • 1/16'' (1.59 mm)
  • 1/8'' (3.18 mm)
  • 3/16'' (4.76 mm)
  • 1/4'' (6.35 mm)

Max. Immersion Length on Request

  • Up to 96" (2438 mm)
  • others on request

Material Protection Tube/ Thermowell

  • Sensor sheath
  • 316
  • Alloy 600

Optional Coating

  • Not applicable

Process Connection

  • Compression fitting: NPT1/8", NPT1/4"

Tip Shape

  • Straight

Surface Roughness Ra

  • Not defined

Operating Temperature

  • Type T: -270 °C ...370 °C (-454 °F ...698 °F)
  • Type J: -210 °C ...720 °C (-346 °F ...1,328 °F)
  • Type E: -270 °C ...820 °C (-454 °F ...1,508 °F)
  • Type K: -270 °C ...1,150 °C (-454 °F ...2,102 °F)
  • Type N: -270 °C ... 1,150 °C (-454 °F ...2,102 °F)

Max. Process Pressure (static)

  • Standard acc. to ASTM E-230
  • Special acc. to ASTM E-230

Accuracy

  • Standard acc. to ASTM E-230
  • Special acc. to ASTM E-230

Response Time

  • 63% rt = 0.3 s

Integration Head Transmitter

  • no
show more