Radiometric Point Level Detection Gammapilot FTG20

Brand: Endress+Hauser

Radiometric Point Level Detection Gammapilot FTG20

Brand: Endress+Hauser
Lean Lean

The Gammapilot FTG20 is the world’s most advanced Geiger-Mueller counter with highest available sensitivity and outstanding features. Even under extreme process conditions like high pressure, high temperature, corrosiveness, toxicity and abrasion, the radiometric measuring principle can be employed without any problems.

For liquids, solids, suspensions and sludges etc. Particularly for applications under extreme measuring conditions, e.g. high pressure, high temperature, corrosiveness, toxicity, abrasion. All kinds of process vessels, e.g. reactors, autoclaves, separators, acid tanks, mixers, cyclones, cupola furnaces.

  • Temperature: No limitation (non-invasive, extraneous)
  • Pressure: No limitation (non-invasive, extraneous)
  • Switch time: Up to 0.4 seconds
  • International explosion protection certificates
Features
  • Sensor and transmitter: One instrument for all measuring tasks - can be used universally due to numerous certificates and approvals
  • Highest availability, reliability and safety, even for extreme process and ambient conditions
  • No recalibration after electronics exchange because of HistoROM data management concept and automatic decay compensation
  • Optimum adjustment to the respective application via a variety of sensitivity versions
  • Relay, 8/16mA (passive - two-wire loop powered) or 4 to 20mA output for easy system integration
  • Aluminum or stainless steel housing for heavy-duty applications
  • Easy commissioning and fast, on-site operation

Specifications

Measuring Principle

  • Radiometric Limit

Characteristic / Application

  • Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions

Specialities

  • Calculation and sizing with Applicator

Supply / Communication

  • Relay DPDT: 19...253 VAC, 19...55 VDC
  • 8/16 mA: 11...36 VDC, 11..30 VDC (Exia)

Ambient Temperature

  • Relay DPDT: 19...253 VAC, 19...55 VDC
  • 8/16 mA: 11...36 VDC, 11..30 VDC (Exia)

Process Temperature

  • Any

Process Pressure / Max. Overpressure Limit

  • Any

Min. Density of Medium

  • Any

Min. Conductivity of Medium

  • Any

Main Wetted Parts

  • Non-contact

Process Connection

  • Non-contact

Process Connection Hygienic

  • Non-contact

Sensor Length

  • 140 mm (5.5")

Communication

  • Relay DPDT
  • 8/16mA
  • 4...20mA

Certificates / Approvals

  • ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC

Options

  • Sensitivity - 1x Geiger- counter: 1-8uSv/h,
  • Sensitivity - 2x Geiger- counter: 0.5-4uSv/h
  • Sensitivity - 3x Geiger- counter: 0.3-2.7uSv/h
  • Cooling jacket
  • Transmitter with compartment for conduit

Components

  • Isotope: FSG60, FSG61
  • Source container: FQG60, FQG61, FQG62, FQG63, QG2000
show more