Hydrostatic Level Measurement Deltapilot FMB70
Brand: Endress+HauserHydrostatic Level Measurement Deltapilot FMB70
Brand: Endress+Hauser
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
- Process connections: Threads, flanges and hygienic connections
- Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
- Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
- Accuracy: ±0.075%
- International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
- Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
- Best batch-to-batch repeatability and long-term stability
- Modular concept for easy replacement of display or electronics
- HistoROM/M-DAT data backup for instrument settings and measured values
- Function-monitored from the measuring cell to the electronics
- Seamless and independent system integration (HART/PA/FF)
- International usage thanks to a wide range of approvals
Specifications
Brand
Measuring Principle
- Hydrostatic pressure
Characteristic
- Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
- Compact version
Supply Voltage
- 4...20 mA HART
- 10.5...45 VDC (Non Ex): Ex ia: 10.5...30 VDC
- PROFIBUS PA: 9...32 VDC (Non Ex)
- FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Reference Accuracy
- Standard 0.1%
- Optional 0.075%
Long Term Stability
- 0.05 % of URL/year
Process Temperature
- -10°C...100°C
- (14°F...212°F)
Ambient Temperature
- -40°C...85°C
- (-40°F...185°F)
Measuring Cell
- 100 mbar...10 bar
- (1.5 psi...150 psi)
Smallest Calibratable Span
- 25 mbar (3.63 psi)
Vacuum Resistance
- 0 mbar abs.
Max. Overpressure Limit
- 40 bar (600 psi)
Process Connection
- Flange: DN40...DN100, ASME 1-1/2"...4", JIS 10K
- Thread: G1-1/2, MNPT1/2
Process Connection Hygienic
- Tri-Clamp
- DIN11851
- DIN11864-1
- NEUMO
- Varivent N
- SMS
- DRD
Material Process Membrane
- 316L, AlloyC
- Gold-Rhodium
Material Gasket
- None, measuring cell welded
Fill Fluid
- Inert oil
- Synthetic oil
Material Housing
- 316L, Die-cast aluminum
Communication
- 4 ... 20 mA HART
- PROFIBUS PA
- FOUNDATION Fieldbus
Certificates / Approvals
- ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety Approvals
- SIL
Design Approvals
- EN10204-3.1
- NACE MR0175
- MR0103
Hygienic Approvals
- 3A, EHEDG
- CoC ASME-BPE
Marine Approvals
- GL, DNV
Drinking Water Approvals
- NSF
Specialities