Absolute and Gauge Pressure Cerabar PMC21

Brand: Endress+Hauser

Absolute and Gauge Pressure Cerabar PMC21

Brand: Endress+Hauser
Fundamental Fundamental

The Cerabar PMC21 is a very compact pressure transmitter. It features a capacitive, oil-free ceramic sensor and is able to measure absolute or gauge pressure from 100 mbar up to 40 bar.

It is designed to withstand the harsh conditions in the process industry with ingress protection grades up to IP68 and highly abrasion resistant Ceraphire membrane as well as high quality 316L housing.

It can be used in most areas as it offers various certifications like hazardous area or marine certificates.

  • Process connections: Threads
  • Process temperature: -25 to +100 °C (-13 to +212 °F)
  • Process pressure: 100mbar to +40 bar (1.5 to +600 psi)
  • Accuracy: ±0.3% of span
  • International explosion protection certificates, marine approvals, cleaning for oxygen applications
Features
  • Easy and time-saving installation and set up within the plant due to very compact construction and customizable measuring ranges
  • High reference accuracy of 0.3% together with high long- term stability and repeatability ensures a high quality of process monitoring. High quality guaranteed by 100% test coverage during production
  • The high process availability even in difficult process environment is guaranteed due to various cleaning options and connection options. Furthermore IP68 version are available
  • The need for documentation and traceability as well as safety in the plant can be supported by PMC21 as it ensures the compliance to various hazardous area and marine certifications and features optional EN10204 3.1 material certificates

Specifications

Measuring Principle

  • Absolute and gauge pressure

Characteristic

  • Cost effective pressure transducer, capacitive sensor with ceramic measuring diaphragm

Supply Voltage

  • 10…30 VDC

Reference Accuracy

  • 0.3 %

Long term Stability

  • 0.2 % of URL/year

Process Temperature

  • -25 °C…+100 °C (-13 °F....+185 °F)

Ambient Temperature

  • -40 °C…+85 °C (-40 °F....+185 °F)

Measuring Cell

  • +100 mbar…+40 bar (+1.5 psi...+600 psi)

Max. Overpressure Limit

  • max. 60 bar (900 psi)

Process Connection

  • G1/4, G1/2
  • MNPT 1/4, MNPT 1/2
  • DIN13
  • JIS R1/2

Communication

  • 4...20 mA, IO-Link

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex

Design Approvals

  • EN 10204-3.1 Final inspection report
  • Cleaned from oil and grease
  • Cleaned for oxygen applications

Marine Approvals

  • RINA, KR
show more