Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.

  • Wide range of applications
  • Measuring range: -50 to +650 °C (-58 to +1202 °F)
  • Pressure range: up to 50 bar (725 psi)
  • Protection class: up to IP68
  • For use in non-hazardous areas
Features
  • Excellent value for money and fast global delivery
  • User-friendly product selection, smart design for easy maintenance
  • Wide range of process connections
  • Bluetooth® connectivity (optional)

Specifications

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • Basic technologie
  • metric style
  • universal range of application
  • direct process contact

Thermowell / Protection Tube

  • without, direct process contact

Insert / Probe

  • Basis Sensortechnologie

Outer Diameter Protection Tube / Insert

  • Insert: 6.0 mm

Max. Immersion Length on Request

  • up to 1,000.0 mm (39'')

Material Protection Tube/ Thermowell

  • Insert Material: 316L (1.4404), Alloy 600 (2.4816)

Process Connection

  • Thread: G1/2", G1/4" NPT1/2", M18x1.5, M20x1.5
  • Compression fitting, also spring load: NPT1/2", G1/2"
  • Cap-nut: G1/2", G3/4"

Tip Shape

  • straight

Operating Temperature

  • Basic PT100 TF: -50 °C …200 °C (-58 °F …392 °F)
  • Typ K: max. 1,100 °C (max. 2,012 °F)

Max. Process Pressure (static)

  • depending on the configuration

Accuracy

  • Class A acc. to IEC 60751
  • Class B acc. to IEC 60751
  • Class standard acc. to ASTM E230
  • Class 2 acc. to IEC 60584-2

Response Time

  • t90 around 17 s
  • depending on configuration

Integration Head Transmitter

  • yes (4 … 20 mA; HART)
show more