Proline Promass F 300 Coriolis Flowmeter

Brand: Endress+Hauser

Proline Promass F 300 Coriolis Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended
Heartbeat Technology Heartbeat Technology

Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments, it is suited for the broadest range of applications. with its compact transmitter Promass F 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Highest measurement performance for liquids and gases under varying, demanding process conditions

Device properties

  • Mass flow: measurement error ±0.05 % (PremiumCal)
  • Medium temperature: -196 to 350 °C (-320 to 662 °F)
  • Nominal diameter: DN 8 to 250 (3/8 to 10")
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Features
  • Highest process safety – immune to fluctuating and harsh environments
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Product Family

  • Promass

Measuring Principle

  • Coriolis

Product Headline

  • Flowmeter with premium accuracy, robustness and a compact, easily accessible transmitter.
  • Highest measurement performance for liquids and gases under varying, demanding process conditions.

Sensor Features

  • Highest process safety – immune to fluctuating and harsh environments
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space‐saving installation – no in-/outlet run needs
  • Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (3/8 to 10")

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available

Nominal Diameter Range

  • DN 8 to 250 (3/8 to 10")

Wetted Materials

  • Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
  • Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)

Measured Variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. Measurement Error

  • Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.25 %
  • Density (liquid): ±0.0005 g/cm³

Measuring Range

  • 0 to 2,200 000 kg/h (0 to 80,840 lb/min)

Max. Process Pressure

  • PN 100, Class 600, 63K

Medium Temperature Range

  • Standard: –50 to +150 °C (–58 to +302 °F)
  • Option: –50 to +240 °C (–58 to +464 °F)
  • High temperatur option: –50 to +350 °C (–58 to +662 °F)
  • Option: –196 to +150 °C (–320 to +302 °F)

Ambient Temperature

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor Housing Material

  • Standard: 1.4301 (304)
  • Option: 1.4404 (316/316L)

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of Protection

  • Compact version: IP66/67, type 4X enclosure
  • External WLAN antenna: IP67
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product Safety

  • CE, C-tick, EAC marking

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
  • NTEP (Liquids other than water, LPG, cryogenic liquids)
  • MC (Liquids other than water, gases, cryogenic liquids)
  • MI-002, PTB

Marine Approvals and Certificates

  • LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure Approvals and Certificates

  • PED, CRN, AD 2000

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Hygienic Approvals and Certificates

  • 3-A, EHEDG, cGMP
show more