Electronic Differential Pressure Deltabar FMD71
Brand: Endress+HauserElectronic Differential Pressure Deltabar FMD71
Brand: Endress+Hauser
The electronic dp Deltabar FMD71 is a differential pressure system, used to measure the pressure or level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.
For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.
- Process connections: Threads, flanges and hygienic connections
- Process temperature: -40 up to +150°C (-40 to +302°F)
- Measuring range: 100mbar to +40bar (6 to 600psi)
- Accuracy: Single sensor up to ±0.05%, system up to ±0.07%
- International explosion protection certificates, hygienic approvals
- Eliminates traditional mechanical issues resulting in greater process availability and reliability
- Overload-resistant high purity ceramic sensor (99.9% Al2O3)
- Safety risks are minimized with the new electronic differential pressure system architecture and design
- Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements
- Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system
- Continuous health indication of the entire system via HART-based diagnostic
- High reproducibility and long-term stability
Specifications
Brand
Measuring Principle
- Differential pressure
Characteristic
- Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids
Supply Voltage
- 4...20 mA HART: 12...45 VDC (Non Ex), Ex ia: 12...30 VDC
Reference Accuracy
- 0.075% of individual sensor
- "PLATINUM" 0.05% of individual sensor
Long Term Stability
- 0.05% of URL/year of individual sensor
Process Temperature
- –25...+150°C
- –13...+302°F
Ambient Temperature
- –40...+80°C
- –40...+176°F
Measuring Cell
- 100 mbar...40 bar
- 1.5 psi...600 psi
Vacuum Resistance
- 0 mbar
Max. Turn Down
- 100 : 1
Max. Overpressure Limit
- 60 bar (900 psi)
Process Connection
- Threads
- Flansch (DIN, ASME, JIS)
Process Connection Hygienic
- DIN11851
- DIN11864-1
- Tri-Clamp
- DRD
- Varivent
Material Process Membrane
- Ceramic
- 316L, AlloyC
Material Gasket
- Viton, Kalrez, EPDM, NBR, Silicone
Fill Fluid
- Silicone Oil
Material Housing
- Die-cast aluminum
- Stainless steel
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
Design Approvals
- NACE MR0175
- EN10204-3.1
Hygienic Approvals
- EHEDG
- 3A