Capacitance Point Level Detection Minicap FTC262

Brand: Endress+Hauser

Capacitance Point Level Detection Minicap FTC262

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Fundamental Fundamental

Minicap FTC262 is a simple and cost-effective rope probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up.

It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30 mm and a dielectric constant εr ≥ 1.6.

  • Process connection: Threads
  • Temperature: -40 to +80 °C (-40 to +176 °F)
  • Pressure: -1 to +6 bar (-14.5 to +90 psi)
  • Sensor length: 500 mm (20") to 6,000 mm (236")
  • International explosion protection certificates, overfill prevention WHG
Features
  • Simple mounting and commissioning without calibration
  • Mechanical safety, cost-efficiency and long operating life due to no wearing parts
  • High operational safety and reliability due to active build-up compensation
  • Optimized storage by simply shortening the rope probe on site

Specifications

Product Family

  • Minicap

Measuring Principle

  • Capacitive Solid

Characteristic / Application

  • No calibration on start-up
  • Active build-up compensation
  • Mechanically robust
  • The rope probe can be shortened (optimum matching to the measuring point)

Specialities

  • Rope shortening parts to be supplied by the customer

Supply / Communication

  • 10.8 ... 45 VDC, DC-PNP 3-wire
  • 20 ... 253 VAC, or 20 ... 55 VDC, Relay output

Ambient Temperature

  • -40...+70 °C (-40...+158 °F)

Process Temperature

  • -40...+80 °C (-40...+176 °F)

Process Pressure / Max. Overpressure Limit

  • -1 ... 6 bar (-14.5 ... 90 psi)

Main Wetted Parts

  • PPS = Polyphenylene sulphide (glass fibre content approx. 40%)

Max. Tensile Strength

  • 3000 N

Process Connection

  • R 1 1/2
  • NPT 1 1/2

Sensor Length

  • min. 500 mm (20"), max 6000 mm (236")

Communication

  • PNP transistor output
  • Relay output (potential-free change-over contact / SPDT)

Certificates / Approvals

  • ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex

Options

  • Aluminium Housing

Application Limits

  • Solids, grain size max. 30 mm (1.2"), DK min 1.5
  • Flexural strength 1400 N (at probe tip)
show more