Guided Radar Measurement Time-Of-Flight Levelflex FMP53

Brand: Endress+Hauser

Guided Radar Measurement Time-Of-Flight Levelflex FMP53

Brand: Endress+Hauser
Extended Extended
Heartbeat Technology Heartbeat Technology

Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.

Version with rod probe.

  • Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO,Varivent N, SMS)
  • Temperature: -20 to +150°C (-4 to +302°F)
  • Pressure: -1 to +16bar (-14.5 to +232psi)
  • Maximum measuring range: Rod 6m (20ft)
  • Accuracy: ±2mm (0.12")
  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol
Features
  • Reliable measurement even for changing product and process conditions
  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
  • Highest reliability due to new Multi-Echo Tracking evaluation
  • Hardware and software developed according to IEC 61508 up to SIL3
  • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
  • Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
  • World's easiest proof test for SIL and WHG saves time and costs

Specifications

Measuring Principle

  • Guided radar

Characteristic / Application

  • Premium device. Hygiene
  • Rod probe
  • ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head

Specialities

  • Heartbeat Technology
  • Bluetooth commissioning
  • Operation and maintenance SmartBlue App
  • HistoROM
  • RFID TAG for easy identification

Supply / Communication

  • 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
  • 4-wire (HART)
  • Bluetooth® wireless technology and App (optional)

Accuracy

  • Rod probe: +/- 2 mm (0.08 in)

Ambient Temperature

  • -20...+80 °C
  • -4...+176 °F

Process Temperature

  • -20...+150 °C
  • -4...+302 °F

Process Pressure / Max. Overpressure Limit

  • Vacuum...16 bar
  • Vacuum...232 psi

Main Wetted Parts

  • Rod probe: 304, 304L, 316L, PEEK

Process Connection

  • Thread: M24

Process Connection Hygienic

  • Tri-Clamp DIN11851, DIN11864-1
  • NEUMO
  • Varivent N
  • SMS

Sensor Length

  • Rod probe: 6 m (20 ft)

Max. Measurement Distance

  • Rod: 6 m (20 ft)
  • Min DK>1.6

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus
  • Bluetooth® wireless technology

Certificates / Approvals

  • ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

Safety Approvals

  • Overfill protection WHG
  • SIL

Design Approvals

  • EN 10204-3.1

Hygienic Approvals

  • 3A, EHEDG
  • CoC ASME-BPE

Options

  • Sensor remote with 3 m/9 ft or 6 m/18 ft cable
  • Weld-in adpater
  • Remote operation via SmartBlue App using Bluetooth®
show more