Cubemass Coriolis Flowmeter
Brand: Endress+HauserCubemass Coriolis Flowmeter
Brand: Endress+HauserCubemass is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass as compact Coriolis sensor.
- Measuring principle operates independently of physical fluid properties such as viscosity or density
- Measuring accurately smallest quantities of liquids and gases
Device properties
- Nominal diameter: DN 1 to 6 (1/24 to 1/4")
- Process pressure up to 400 bar (5800 psi)
- Medium temperature up to +200 °C (+392 °F)
- Robust transmitter housing
- Modbus RS485
- Pulse output
- Measuring accurately smallest quantities of liquids and gases
- Space-saving installation – compact single-tube design
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Suitable for skids – lightweight sensor
- Cost savings – very low power consumption
- Fast commissioning – pre-configured devices
- Automatic recovery of data for servicing
Specifications
Brand
Measuring Principle
- Coriolis
Product Headline
- Compact sensor for smallest quantities with easy system integration
- Measuring accurately smallest quantities of liquids and gases
Sensor Features
- Space-saving installation - Compact single-tube design
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Suitable for skids – lightweight sensor
- Nominal diameter: DN 1 to 6 (1/24" to 1/4"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F)
Transmitter Features
- Cost savings – very low power consumption
- Fast commissioning – pre-configured devices. Automatic recovery of data for servicing
- Robust transmitter housing. Modbus RS485. Pulse output
Nominal Diameter Range
- DN 1 to 6 (1/24" to 1/4")
Wetted Materials
- Measuring tube: 1.4539 (904L)
- Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured Variables
- Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. Measurement Error
- Mass flow (liquid): ±0.1 %
- Volume flow (liquid): ±0.1 %
- Mass flow (gas): ±0.5 %
- Density (liquid): ±0.0005 g/cm3
Measuring Range
- 0 to 1000 kg/h (0 to 37 lb/min)
Max. Process Pressure
- PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium Temperature Range
- –50 to +200 °C (–58 to +392 °F)
Ambient Temperature
- Standard: –20 to +60 °C (–4 to +140 °F)
- Option: –40 to +60 °C (–40 to +140 °F)
Sensor Housing Material
- 1.4301 (304), corrosion resistant
Transmitter Housing Material
- Powder‐coated die‐cast aluminium
Degree of Protection
- IP67, type 4X enclosure
Display/Operation
- No local operation
- Configuration via operating tools possible
Outputs
- Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs
- None
Digital Communication
- Modbus RS485
Power Supply
- DC 10 to 30 V
- AC 20 to 28 V
Hazardous Area Approvals
- ATEX, IECEx, NEC/CEC, NEPSI
Other Approvals and Certificates
- 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
- CRN
Metrological Approvals and Certificates
- 3.1 material
Pressure Approvals and Certificates
- CRN