CNGmass DCI Coriolis Flowmeter

Brand: Endress+Hauser

CNGmass DCI Coriolis Flowmeter

Brand: Endress+Hauser

CNGmass DCI is specially designed for refueling with environmentally friendly natural gas (CNG). The natural gas volume can be both measured with precision and displayed directly onsite. The device is operated from the outside via “Touch Control” and can be operated at any time during maintenance. A MODBUS interface is included for optimal data exchange.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Accurate measurement of compressed natural gas (CNG) in high-pressure refueling applications

Device properties

  • Flow rates up to 150 kg/min (330 lb/min)
  • Process pressure up to 350 bar (5080 psi)
  • Rupture disc available
  • Robust, ultra-compact transmitter housing
  • Pulse output and Modbus RS485
  • Transmitter for custody transfer
Features
  • Excellent operational safety – reliable under extreme process conditions
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in/outlet run needs
  • High flexibility in system integration – wide range of communication interfaces
  • Fast commissioning – pre-configured devices
  • Automatic recovery of data for servicing

Specifications

Measuring Principle

  • Coriolis

Product Headline

  • The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications

Sensor Features

  • Fewer process measuring points – multivariable measurement (flow, density, temp)
  • Space‐saving installation – no in/outlet run needs
  • Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi)
  • Excellent operational safety – reliable under extreme process conditions

Transmitter Features

  • High flexibility in system integration – wide range of communication interfaces
  • Fast commissioning – preconfigured devices
  • Device in compact or remote version
  • Flexible outputs and Modbus RS485
  • Automatic recovery of data for servicing

Nominal Diameter Range

  • DN 8 to 25 (3/8 to 1")

Wetted Materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4404 (316)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Max. Measurement Error

  • Mass flow: ±0.5 % of batch

Measuring Range

  • 0 to 150 kg/min (0 to 330 lb/min)

Max. Process Pressure

  • 350 bar (5080 psi)

Medium Temperature Range

  • –50 to +150 °C (–58 to +302 °F)

Ambient Temperature

  • Standard: –20 to +60 °C (–4 to +140 °F)
  • Option: –40 to +60 °C (–40 to +140 °F)

Sensor Housing Material

  • 1.4301 (304), corrosion resistant

Transmitter Housing Material

  • Powder‐coated die‐cast aluminium

Degree of Protection

  • Remote transmitter: IP67, type 4X enclosure
  • IP67, type 4X enclosure

Display/Operation

  • 4‐line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible

Outputs

  • 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive)
  • Pulse/frequency/switch output (passive), phase‐shifted pulse
  • Relay

Inputs

  • 1 modular input: status

Digital Communication

  • HART, Modbus RS485

Power Supply

  • DC 16 to 62 V
  • AC 85 to 260 V (45 to 65 Hz)
  • AC 20 to 55 V (45 to 65 Hz)

Hazardous Area Approvals

  • ATEX, IECEx, NEPSI, JPN

Other Approvals and Certificates

  • 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
  • CRN

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer

Pressure Approvals and Certificates

  • CRN

Material Certificates

  • 3.1 material
show more