Proline T-Mass B 150 Thermal Mass Flowmeter

Brand: Endress+Hauser

Proline T-Mass B 150 Thermal Mass Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Lean Lean

The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement
  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts

Device properties

  • Insertion version for nominal diameter DN 80 to 1500 (3 to 60")
  • Installation and removal of sensor without process interruption
  • Easy installation
  • Device in compact version with DC 24 V power supply
  • 4-20 mA HART, pulse/frequency/switch output
  • Compact and robust transmitter
Features
  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
  • Optimal process monitoring – easy measurement even at low pressures and flow velocities
  • Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
  • Reliable flow trending – multivariable measurement
  • Fast and efficient commissioning – guided operating menus
  • High plant availability – self-diagnostics and error monitoring
  • Automatic recovery of data for servicing

Specifications

Product Family

  • T-mass

Measuring Principle

  • Thermal

Product Headline

  • The flowmeter for cost-effective measurement and easy monitoring of utility gases
  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts

Sensor Features

  • Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement
  • Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation

Transmitter Features

  • Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing
  • Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter

Nominal Diameter Range

  • DN 80 to 1500 (3 to 60")

Wetted Materials

  • Transducer: 1.4404 (316L)
  • Insertion tube: 1.4404 (316L); 1.4435 (316L)
  • Compression fitting: 1.4404 (316L)
  • Sealing ring: EPDM; HNBR; 1.4401 (316)
  • Clamping ring: PEEK 450G

Measured Variables

  • Mass flow, temperature, corrected volume flow, FAD volume flow

Max. Measurement Error

  • 3 % o.r.
  • 4 % o.r.
  • 5 % o.f.s.
  • depending on chosen option of ordering feature "Calibration flow"

Measuring Range

  • 20 to 720,000 kg/h (45 to 1,587,600 lb/h)
  • 20 to 1,080,000 kg/h (45 to 2,381,400 lb/h)
  • for air, depending on chosen option of ordering feature "Calibration flow"

Max. Process Pressure

  • 20 bar g (290 psi g)

Medium Temperature Range

  • –40 to +100 °C (–40 to +212 °F)

Ambient Temperature

  • –40 to +60 °C (–40 to +140 °F)

Transmitter Housing Material

  • AlSi10Mg, coated

Degree of Protection

  • IP66/67, type 4X enclosure

Display/Operation

  • 4‐line display with push Buttons
  • Configuration via local display and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • Status input

Digital Communication

  • HART

Power Supply

  • DC 18 to 30 V

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

Pressure Approvals and Certificates

  • CRN
show more