The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement
- Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
Device properties
- Insertion version for nominal diameter DN 80 to 1500 (3 to 60")
- Installation and removal of sensor without process interruption
- Easy installation
- Device in compact version with DC 24 V power supply
- 4-20 mA HART, pulse/frequency/switch output
- Compact and robust transmitter
- Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
- Optimal process monitoring – easy measurement even at low pressures and flow velocities
- Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
- Reliable flow trending – multivariable measurement
- Fast and efficient commissioning – guided operating menus
- High plant availability – self-diagnostics and error monitoring
- Automatic recovery of data for servicing
Specifications
Brand
Measuring Principle
- Thermal
Product Headline
- The flowmeter for cost-effective measurement and easy monitoring of utility gases
- Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
Sensor Features
- Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement
- Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation
Transmitter Features
- Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing
- Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter
Nominal Diameter Range
- DN 80 to 1500 (3 to 60")
Wetted Materials
- Transducer: 1.4404 (316L)
- Insertion tube: 1.4404 (316L); 1.4435 (316L)
- Compression fitting: 1.4404 (316L)
- Sealing ring: EPDM; HNBR; 1.4401 (316)
- Clamping ring: PEEK 450G
Measured Variables
- Mass flow, temperature, corrected volume flow, FAD volume flow
Max. Measurement Error
- 3 % o.r.
- 4 % o.r.
- 5 % o.f.s.
- depending on chosen option of ordering feature "Calibration flow"
Measuring Range
- 20 to 720,000 kg/h (45 to 1,587,600 lb/h)
- 20 to 1,080,000 kg/h (45 to 2,381,400 lb/h)
- for air, depending on chosen option of ordering feature "Calibration flow"
Max. Process Pressure
- 20 bar g (290 psi g)
Medium Temperature Range
- –40 to +100 °C (–40 to +212 °F)
Ambient Temperature
- –40 to +60 °C (–40 to +140 °F)
Transmitter Housing Material
- AlSi10Mg, coated
Degree of Protection
- IP66/67, type 4X enclosure
Display/Operation
- 4‐line display with push Buttons
- Configuration via local display and operating tools possible
Outputs
- 4‐20 mA HART (active)
- Pulse/frequency/switch output (passive)
Inputs
- Status input
Digital Communication
- HART
Power Supply
- DC 18 to 30 V
Hazardous Area Approvals
- ATEX, IECEx, cCSAus
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure Approvals and Certificates
- CRN