iTEMP TMT72 Temperature Transmitter

Brand: Endress+Hauser

iTEMP TMT72 Temperature Transmitter

Brand: Endress+Hauser
Lean Lean

Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART ® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth ® interface for remote operation via Endress+Hauser SmartBlue App.

  • Bluetooth®-enabled temperature transmitter with HART®communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal
  • Improved process efficiency and increased plant uptime
  • Universal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)
  • Installation in terminal head form B (flat face) as per DIN EN 50446
  • Installation in cabinets with DIN rail housing
  • Optional installation in field housing even for use in Ex d applications
Features
  • Safe operation in hazardous areas thanks to international approvals
  • Reliable operation thanks to sensor and device monitoring
  • Integrated Bluetooth®interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional
  • Diagnostics information according to NAMUR NE 107
  • Available with plug-on display TID10
  • Optimization of the measurement accuracy by sensor-transmitter matching.

Specifications

Measuring Principle

  • Head transmitter

Input

  • 1 x RTD, TC, Ohm, mV

Output

  • 1 x analog 4...20 mA / HART

Auxiliary Power Supply

  • 10...36 VDC (Head transmitter)
  • 11...36 VDC (DIN rail device)
  • 10/11...30 VDC (Ex ia)

Communication

  • HART-protocol
  • Bluetooth® wireless technology

Installation

  • Terminal head form B / DIN rail / field mount housing

Accuracy

  • (Pt100, -50...200 °C) <= 0.1 K
  • (Pt100, -58...392 °F) <= 0.18 °F

Galvanic Isolation

  • yes

Certification

  • ATEX Ex ia, Ex ic, Ex tc, Ex nA, Ex db, Ex tb
  • ATEX IECEx Ex ia, Ex tb
  • IECEx Ex d, Ex tb
  • CSA C/US General Purpose
  • CSA C/US IS, Ex ec, XP, DIP
  • INMETRO Ex ia, Ex d, Ex tb
  • NEPSI Ex ia, Ex d, Ex tb
  • EAC Ex ia, Ex d
  • UKCA Ex ia, Ex tc, Ex nA, Ex db, Ex tb
show more