Hydrostatic Level Measurement Deltapilot FMB50
Brand: Endress+HauserHydrostatic Level Measurement Deltapilot FMB50
Brand: Endress+Hauser
The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
For level and/or pressure measurement.
- Process connections: Thread, flanges and flush-mounted hygienic connections
- Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
- Measuring range: 0.1 to 10bar (1.5 to 150psi)
- Accuracy: ±0.2%, ±0.1% (option)
- International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates
- Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
- Modular concept for easy replacement of display or electronics
- Seamless and independent system integration (HART/PA/FF)
- Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- International usage thanks to a wide range of approvals
Specifications
Brand
Measuring Principle
- Hydrostatic pressure
Characteristic
- Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Supply Voltage
- 4...20 mA HART
- 10.5...45 VDC (Non Ex): Ex ia: 10.5...30 VDC
- PROFIBUS PA: 9...32 VDC (Non Ex)
- FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
Reference Accuracy
- Standard 0.2 %
- Optional 0.1 %
Long Term Stability
- 0.05 % of URL/ year
Process Temperature
- -10°C...100°C
- (14°F...212°F)
Ambient Temperature
- -40°C...85°C
- (-40°F...185°F)
Measuring Cell
- 100 mbar...10 bar
- (1.5 psi...150 psi)
Smallest Calibratable Span
- 10 mbar (1.45 psi)
Vacuum Resistance
- 0 mbar abs.
Max. Turn Down
- 100:1
Max. Overpressure Limit
- 40 bar (600 psi)
Process Connection
- Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K
- Thread: G1-1/2, MNPT1-1/2
Process Connection Hygienic
- Tri-Clamp
- DIN11851
- DIN11864-1
- NEUMO
- Varivent N
- SMS
- DRD
Material Process Membrane
- 316L, AlloyC
- Gold-Rhodium
Material Gasket
- None, measuring cell welded
Fill Fluid
- Inert oil,
- Synthetic oil
Material Housing
- 316L, Die-cast aluminum
Communication
- 4...20 mA HART
- PROFIBUS PA
- FOUNDATION Fieldbus
- IO-Link
Certificates / Approvals
- ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety Approvals
- Overfill protection WHG
- SIL
Design Approvals
- EN10204-3.1
- NACE MR0103
Hygienic Approvals
- 3A, EHEDG
- CoC ASME-BPE
Marine Approvals
- GL/ ABS/ LR/ BV/ DNV
Drinking Water Approvals
- KTW/ NSF/ ACS
Specialities
- Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
- Diagnostic functions