Orthophosphate Analyzer Liquiline System CA80PH
Brand: Endress+HauserOrthophosphate Analyzer Liquiline System CA80PH
Brand: Endress+Hauser
Liquiline System CA80PH offers online orthophosphate measurement for precise dosing of precipitants in wastewater treatment. As all Liquiline System analyzers, it enables plug & play of up to 4 Memosens sensors - minimizing the installation effort. Automatic calibration and cleaning and the low consumption of reagents save you operating costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
Liquiline System CA80PH supports you in optimizing the cleaning capacity of wastewater treatment plants. It monitors and controls:
- Precipitant dosing in aeration basins
- Wastewater treatment plant outlets
In industrial applications, Liquiline System CA80PH is used for the monitoring of cooling water cycles.
Features- Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation
- Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors
- Advanced diagnostics with remote access for increased process safety
- Reduced operating costs through automatic calibration and cleaning and long reagent shelf life with cooling module
- Available with both standardized measuring methods covering all applications: Molybdenum blue method and Molybdate Vanadate yellow method
Specifications
Brand
Measuring Principle
- Colorimetric
Characteristic
- Process analyzer for orthophosphate in aqueous solutions
- Comply with standard colorimetric measuring principle, molybdenum blue method, following DIN EN 1189 or molybdate vanadate method
Size
- Housing (open version): 793 x 530 x 417 mm (31.22 x 20.87 x 16.42 in)
- Housing (closed version): 793 x 530 x 463 mm (31.22 x 20.87 x 18.23 in)
- Housing with base: 1723 x 530 x 463 mm (67.83 x 20.87 x 18.23 in)
Design
- Open design, cabinet and stand housing
- High-Performance plastic ASA-PC, additional stand coated steel
Process Temperature
- 4 to 40 °C (39.2 to 104 °F)
Ambient Temperature
- 5 to 40 °C (41 to 104 °F)
- Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process Pressure
- At atmospheric pressure, < 0.2 bar
Sample Flow Rate
- Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the Sample
- Suspended solids content
- Turbitity < 50 NTU, aqueous, homogenized
Application
- Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants
Power Supply
- 100 to 120 VAC / 200 to 240 VAC ± 10%
- 24 VDC ± 10%
- 50 ± 1 or 60 ± 1.2 Hz
Output / Communication
- 2x 0/4 to 20 mA
- Modbus RS485/TCP
Input
- 1 or 2 measuring channel
- 1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring Range
- 0 to 2.5 mg/l PO4-P (blue method)
- 0.05 to 10 mg/l PO4-P (blue method)
- 0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
- 0.5 to 20 mg/l PO4-P (yellow method)
- 0.5 to 50 mg/l PO4-P (yellow method)
- 0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)
Consumables
- Reagents and standard solutions CY80H as well as cleaner CY800 (blue method) are necessary for the operation
- Regular maintenance is done with the parts of the maintenance kit CAV800