Guided Radar Measurement Time-Of-Flight Levelflex FMP54
Brand: Endress+HauserGuided Radar Measurement Time-Of-Flight Levelflex FMP54
Brand: Endress+Hauser

Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.
Version with rod, rope or coax probe.
- Process connections: Thread or flange
- Temperature: -196 to +450°C (-320 to +842°F)
- Pressure: -1 to +400bar (-14.5 to +5,800psi)
- Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
- Accuracy: rod ±2mm (0.08")
- International explosion protection certificates, overfill prevention WHG, SIL, marine approval, steam boiler approval, 5-point linearity protocol
- Reliable measurement even for changing product and process conditions
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Highest reliability due to new Multi-Echo Tracking evaluation
- Hardware and software developed according to IEC 61508 up to SIL3
- Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
- Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
- World's easiest proof test for SIL and WHG saves time and costs
Specifications
Brand
Measuring Principle
- Guided radar
Characteristic / Application
- Premium device high pressure/ high temperature
- Rod probe, Rope probe, Coaxial Probe
- Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias
Interface Measurement
- Clean interfaces liquid/ liquid
- Simultaneous measurement of interface and overall level
Specialities
- Heartbeat Technology
- Bluetooth® commissioning
- Operation and maintenance SmartBlue App
- HistoROM
- RFID TAG for easy identification
Supply / Communication
- 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
- 4-wire (HART)
- Bluetooth® wireless technology and App (optional)
Accuracy
- Rod probe: +/- 2 mm (0.08 in)
- Rope probe ≤ 15 m (49 ft): +/- 2 mm (0.08 in)
- Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
- Coaxial probe: +/- 2 mm (0.08 in)
Ambient Temperature
- -50...+80 °C
- -58...+176 °F
Process Temperature
- XT: -196...+280 °C (-321...+536 °F)
- HT: -196...+450 °C (-321...+842 °F)
Process Pressure / Max. Overpressure Limit
- Vacuum...400 bar
- Vacuum...5800 psi
Main Wetted Parts
- Rod probe: 304, 316L, Alloy C, Ceramic
- Rope probe: 304, 316, 316L, Alloy C, Ceramic
- Coaxial probe: 304, 316L, Alloy C, Ceramic
Process Connection
- Thread; G 1-1/2, MNPT 1-1/2
- Flange: ASME 2"...4", DN50...DN100, JIS 10K, 63K
- Fisher
- Masoneilan
Sensor Length
- Rod probe: 10 m (33 ft)
- Rope probe: 45 m (148 ft)
- Coaxial probe: 6 m (20 ft)
Max. Measurement Distance
- Rod: 10 m (33 ft) Min DK>1.6
- Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1.9
- Coaxial probe: 6 m (20 ft) Min DK>1.4
Communication
- 4...20 mA HART
- PROFIBUS PA
- FOUNDATION Fieldbus
- Bluetooth® wireless technology
Certificates / Approvals
- ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
Safety Approvals
- Overfill protection WHG
- SIL
Design Approvals
- EN 10204-3.1
- NACE MR0175, MR0103
- ASME B31.1, B31.3
- AD2000
- Steam boiler approval
Marine Approval
- GL/ DNV/ ABS/ LR/ BV
Options
- Sensor remote with 3 m/ 9 ft cable,
- Remote operation via SmartBlue App using Bluetooth®