Capacitance Level Measurement Liquicap FMI21
Brand: Endress+HauserCapacitance Level Measurement Liquicap FMI21
Brand: Endress+Hauser
Liquicap FMI21 is a simple and cost-effective rod probe for continuous level measurement for conductive liquids. High quality non-corrosive materials (carbon fibre, stainless steel) make it suitable even for aggressive liquids (e.g. acids and alkalis).
Used in conjunction with the Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
The device is preconfigured from factory 0 to 100% to probe length ordered. It can be used as of a conductivity of 30 μS/cm and the measurement is independent of the dc-value (dielectric constant) of the liquid. Suited for cistern measurements.
- Process connection: Thread
- Process pressure: Vacuum to 10 bar (vacuum to 145 psi)
- Measuring range: Up to 2.5 m (8 ft)
- Temperature: -40 to +100 °C (-40 to +212 °F)
- International explosion protection certificates, overfill prevention WHG
- Safe and reliable function regardless of tank geometry
- No calibration necessary (factory preconfiguration)
- High quality, non-corrosive materials (carbon fibre, stainless steel) for use in aggressive liquids
- No moving parts in tank
- Cost-effective solution for continuous level measurement
- Optimized storage by simply shortening the probe rods on site
Specifications
Brand
Measuring Principle
- Capacitive
Characteristic / Application
- Two-rod probe
- Preconfigured from factory 0%...100%
- High quality, non-corrosive materials (carbon fibre, stainless steel)
- Suitable for aggressive liquids (many acids and alkalis)
Specialities
- Probe shorting kit available
Supply / Communication
- 10 to 30 VDC
Accuracy
- < 1%
Ambient Temperature
- -40...70 °C (-40...158 °F)
Process Temperature
- -40...100 °C (-40...212 °F)
Process Pressure / Max. Overpressure Limit
- Vacuum to 10 bar (145 psi)
Main Wetted Parts
- Probe rods: 316L/1.4404 / PP
- Option: carbon fibre PP coated
Process Connection
- G 1-1/2
- NPT 1-1/2
Sensor Length
- Total length of probe 2.5 m
Max. Measurement Distance
- 2.5 m (8 ft)
Communication
- 4 ... 20 mA
Certificates / Approvals
- ATEX, CSA, CSA C/US
Safety Approvals
- Overfill prevention WHG
Options
- Display
Application Limits
- Changing, non-conductive media, conductivity 2,000 cst