Electronic Differential Pressure Deltabar FMD72

Brand: Endress+Hauser

Electronic Differential Pressure Deltabar FMD72

Brand: Endress+Hauser
Extended Extended

The electronic dp Deltabar FMD72 is a differential pressure system, used to measure the pressure, level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.

For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.

  • Process connections: Threads, flanges and hygienic connections
  • Process temperature: -40 to +125°C (-40 to +257°F), optional 250°C (480°F)
  • Measuring range: 400mbar to +40bar (6 to 600psi)
  • Accuracy: Single sensor up to ±0.05%, system up to ±0.07%
  • International explosion protection certificates, hygienic approvals
Features
  • Eliminates traditional mechanical issues resulting in greater process availability and reliability
  • Safety risks are minimized with the new electronic differential pressure system architecture and design
  • Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements
  • Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system
  • Continuous health indication of the entire system via HART-based diagnostic
  • High reproducibility and long-term stability
  • Process safety assured with small flush mounted process connections in hygienic applications

Specifications

Measuring Principle

  • Differential pressure

Characteristic

  • Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids

Supply Voltage

  • 4...20 mA HART: 12...45 VDC (Non Ex), Ex ia: 12...30 VDC

Reference Accuracy

  • 0.075% of individual sensor
  • "PLATINUM" 0.05% of individual sensor

Long Term Stability

  • 0.05% of URL/year of individual sensor

Process Temperature

  • –40...+125°C
  • –40...+257°F

Ambient Temperature

  • –40...+80°C
  • –40...+176°F

Measuring Cell

  • 400 mbar...10 bar
  • 6 psi...150psi

Vacuum Resistance

  • 10 mbar (0.15 psi)

Max. Overpressure Limit

  • 160 bar (2400 psi)

Process Connection

  • Threads
  • Flange (DIN, ASME, JIS)

Process connection hygienic

  • DIN11851
  • DIN11864-1
  • Tri-Clamp
  • DRD
  • Varivent

Material Process Membrane

  • 316L, AlloyC

Fill Fluid

  • Silicone oil
  • Synthetic oil

Material Housing

  • Die-cast aluminum
  • Stainless steel

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

Design Approvals

  • NACE MR0175
  • EN10204-3.1

Hygienic Approvals

  • EHEDG
  • 3A
show more