Proline Prowirl D 200 Vortex Flowmeter

Brand: Endress+Hauser

Proline Prowirl D 200 Vortex Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Lean Lean
Heartbeat Technology Heartbeat Technology

The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. with genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

  • Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
  • For all basic applications and for 1-to-1 replacement of orifice plates

Device properties

  • Face-to-face length of 65 mm (2.56 in)
  • No flanges
  • Low weight
  • Display module with data transfer function
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Features
  • Integrated temperature measurement for mass/energy flow of saturated steam
  • Easy alignment of the sensor – included centering rings
  • High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer
  • Long-term stability – robust drift-free capacitive sensor
  • Convenient device wiring – separate connection compartment
  • Safe operation – no need to open the device due to display with touch control, background lighting
  • Integrated verification – Heartbeat Technology

Specifications

Product Family

  • Prowirl

Measuring Principle

  • Vortex

Product Headline

  • Cost-effective wafer flowmeter, available as compact or remote version
  • Integrated temperature measurement for mass/energy flow of saturated steam
  • For all basic applications and for 1-to-1 replacement of orifice plates

Sensor Features

  • Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor
  • Face-to-face length of 65 mm (2.56 in). No flanges. Low weight

Transmitter Features

  • Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology
  • Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area)

Nominal Diameter Range

  • DN 15 to 150 (1/2 to 6")

Wetted Materials

  • Measuring tube: 1.4408 (CF3M)
  • DSC sensor: 1.4435 (316/316L)

Measured Variables

  • Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. Measurement Error

  • Volume flow (liquid): ±0.75 %
  • Volume flow (steam, gas): ±1.00 %
  • Mass flow (liquid): ±0.85%
  • Mass flow (steam, gas): ±1.7 %

Measuring Range

  • Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min)
  • depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
  • Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min)
  • depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Max. Process Pressure

  • PN 40, Class 300, 20K

Medium Temperature Range

  • Standard: –40 to +260 °C (–40 to +500 °F)
  • High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
  • High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

Ambient Temperature

  • Compact version (standard): –40 to +80 °C (–40 to +176 °F)
  • Compact version (option): –50 to +80 °C (–58 to +176 °F)
  • Remote version (standard): –40 to +85 °C (–40 to +185 °F)
  • Remote version (option): –50 to +85 °C (–58 to +185 °F)

Sensor Housing Material

  • Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4404 (316L)

Degree of Protection

  • Compact version: IP66/67, type 4X enclosure
  • Sensor remote version: IP66/67, type 4X enclosure
  • Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

  • 4‐line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 4‐20 mA HART (passive)
  • 4‐20 mA (passive)
  • Pulse/frequency/switch output (passive)

Inputs

  • Current input 4‐20 mA (passive)

Digital Communication

  • HART, PROFIBUS PA, FOUNDATION Fieldbus

Power Supply

  • DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
  • DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
  • DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
  • DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, JPN, EAC, UK Ex

Product Safety

  • CE, C-TICK, EAC

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine Approvals and Certificates

  • ABS, LR, BV, DNV

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI (on request)